I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ2 Sensor
₹200.00 Original price was: ₹200.00.₹150.00Current price is: ₹150.00. inc. GST
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ2 sensor also known as Chemiresistor ideal for detection or measuring of LPG, Alcohol, Propane, Hydrogen, CO, and even methane. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality monitors and gas leakage alarm systems. The MQ2 sensor operates at a voltage of 5V DC and draws around 800mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ2 sensor is a Tin oxide semiconductor sensor designed with higher sensitivity to liquefied petroleum gas, propane, hydrogen, and other combustible vapours. It detects gases anywhere in a range from 200 to 10000ppm. This sensor can detect gas either by digital pin or by analogue pin. The digital low signal light is accessed through the IO ports on the Microcontroller. The analogue output is a concentration, i.e. increasing voltage is directly proportional to increasing concentration. By using the external load resistance the resistance variation is converted into a suitable voltage variation. A small potentiometer in this sensor permits the adjustment of the sensitivity of the sensor circuit. This sensor features long life, low cost, and reliable stability make it particularly suitable for Air quality monitoring applications.
MQ2 sensors are enclosed in two-layer stainless steel that provides an Anti Explosion Network. This is enclosed in order to avoid the heater element explosion, as we are sensing flammable gases. It also provides protection for the sensor and filters out suspended particles so that only gaseous elements pass through the chamber.
Applications:
- Detects or measure Gases like LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Air quality monitor
- Gas leak alarm
- Safety standard maintenance
- Maintaining environmental standards in hospitals

Related products
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
Force Sensor 14.7MM
LDR SENSOR 20mm
MQ135 Module
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 10 - 300 ppm NH3, 10 - 1000 ppm Benzene, 10 - 300 Alcohol
- Sensitivity to Ammonia, Sulphide, and Benzene steam
- With signal output instructions
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Sensitive for benzene, alcohol, smoke
- Fast response and recovery
- Adjustable sensitivity
- Signal output indicator
- Dimension: 32mm x 22m x 27mm
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ3 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 0.05 mg/L to 10 mg/L
- Sensitive to Alcohol, Benzine, CH4, Hexane, LPG, CO
- High Sensitivity to Alcohol & small sensitivity to Benzine.
- Digital Out is High or Low based on an adjustable preset threshold,
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant