- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ2 sensor also known as Chemiresistor ideal for detection or measuring of LPG, Alcohol, Propane, Hydrogen, CO, and even methane. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality monitors and gas leakage alarm systems. The MQ2 sensor operates at a voltage of 5V DC and draws around 800mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ2 sensor is a Tin oxide semiconductor sensor designed with higher sensitivity to liquefied petroleum gas, propane, hydrogen, and other combustible vapours. It detects gases anywhere in a range from 200 to 10000ppm. This sensor can detect gas either by digital pin or by analogue pin. The digital low signal light is accessed through the IO ports on the Microcontroller. The analogue output is a concentration, i.e. increasing voltage is directly proportional to increasing concentration. By using the external load resistance the resistance variation is converted into a suitable voltage variation. A small potentiometer in this sensor permits the adjustment of the sensitivity of the sensor circuit. This sensor features long life, low cost, and reliable stability make it particularly suitable for Air quality monitoring applications.
MQ2 sensors are enclosed in two-layer stainless steel that provides an Anti Explosion Network. This is enclosed in order to avoid the heater element explosion, as we are sensing flammable gases. It also provides protection for the sensor and filters out suspended particles so that only gaseous elements pass through the chamber.
Applications:
- Detects or measure Gases like LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Air quality monitor
- Gas leak alarm
- Safety standard maintenance
- Maintaining environmental standards in hospitals

Related products
DS18B20 PROBE
- Usable temperature range: -55 to 125°C (-67°F to +257°F)
- 9 to 12-bit selectable resolution
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into a chip
- Multiple sensors can share one pin
- ±0.5°C Accuracy from -10°C to +85°C
- Temperature-limit alarm system
- Query time is less than 750ms
- Usable with 3.0V to 5.5V power/data
- Each pin uses a heat-shrinkable tube to prevent short circuit, internal sealing glue.
- Stainless steel tube encapsulation waterproof moistureproof prevents rust.
- Stainless steel tube 6mm diameter by 30mm long.
- Contains DS18B20 temperature sensor.
- Uses 1-Wire interface- requires only one digital pin for communication.
- Unique 64 bit ID burned into the chip.
- Multiple sensors can share one pin.
- Temperature-limit alarm system.
- Without the external components, the unique single bus.
Force Sensor 5.08mm
- Two pins extend from the bottom of the sensor with 0.1″ pitch making it bread friendly.
- Device Rise Time: <3 microseconds
- Easily customizable to a wide range of sizes
- Actuation Force: 0.1 Newtons
- Cost-effective
- Ultra-thin; 0.45 mm
- Robust; up to 10 million actuation
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Simple and easy to Integrate.
- Non-Actuated Resistance: 10M W
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
LJ12A3-4-Z/BY PNP DC6-36V 8 mm INDUCTIVE PROXIMITY SENSOR
- Output type: PNP NO
- Supply voltage: 6V-36V
- Current output: 300mA
- Response frequency: 0.5khz
- Detecting distance: 4mm
- Wire type: cylindrical DC 3 wire type
- Switch appearance type: cylinder type
- Operating temperature: -25 degrees to 55 degrees Celsius
- Detect object: iron
- Red led checks proximity status
- High repeated positioning accuracy
- High switching frequency
- Reverse power protection, short circuit protection, directly connecting with PLC
- anti-vibration, dust, water, and oil prevention
- Dimension: 5*3*3cm
- Weight: 400gm
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ6 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Dual signal output (analogue output, and TTL level output)
- Detection Gas: Propane, Butane, and LPG
- Detection range: 300 to 10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller)
- Onboard Power indication
- Good sensitivity to Combustible gas in a wide range
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference.
- Simple drive circuit
- An indication of the signal output
- High sensitivity to hydrogen.
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm