I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
A3144 Hall Effect Sensor
₹110.00 Original price was: ₹110.00.₹60.00Current price is: ₹60.00. inc. GST
- Digital Output Hall-effect sensor
- Operating voltage: 4.5V to 28V (typically 5V)
- Output Current: 25mA
- Can be used to detect both the poles of a magnet
- The output voltage is equal to operating voltage
- Operating temperature: -40°C to 85°C
- Turn on and Turn off time is 2uS each
- Inbuilt reverse polarity protection
- Suitable for Automotive and Industrial Applications
Linear Hall-effect sensor is designed as a compact-sized, versatile linear Hall-effect device operated by the magnetic field from a permanent magnet or an electromagnet. A Hall effect sensor is a transducer that varies its output voltage proportional to the strength of the magnetic field. The integrated circuitry features low noise output, thereby making it unnecessary to use external filtering. The thin-film resistors present on the sensor module provide increased temperature stability and hence provide better accuracy. Thus these Hall-effect sensors offer a wide range of applications in proximity switching, positioning, speed detection, and current sensing applications. In short, it is simply a sensor that operates as an analogue transducer, directly returning a voltage.
A3144 is defined as a digital output hall sensor, meaning if it detects a magnet the output will go low else the output will remain high. Highly recommended to use a pull-up resistor to keep the output high when no magnet is detected. Each device includes a voltage regulator for operation with supply voltages of 4.5 to 24 volts, reverse battery protection diode, quadratic Hall-voltage generator, temperature compensation circuitry, small-signal amplifier, Schmitt trigger, and an open-collector output to sink up to 25 mA. With suitable output pull up, they can be used with bipolar or CMOS logic circuits.
Meanwhile, small geometries of the BiCMOS process allow manufacturing of these sensor modules in ultra-small packages. Moreover, each package is protected by lead (Pb) free, with 100% material tin-plated lead frames. The linear Hall sensor operates at a temperature range of -40 °C to 85 °C, thus making it ideal for commercial, consumer, and industrial environments.
Applications:
- Used to detect magnets(objects) in automation systems
- Used in a magnetic door alarm system
- Measure speed in automobiles
- Detect the pole of magnets in BLDC motors

Related products
ACS712 20A Hall Current Sensor Module SMD SOP8 SOIC8
- Low-noise analog signal path
- Device bandwidth is set via the new FILTER pin
- 5 µs output rise time in response to step input current
- 80 kHz bandwidth
- Total output error 1.5% at TA= 25°C
- Small footprint, low-profile SOIC8 package
- 2 mΩ internal conductor resistance
- 1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8
- 0 V, single supply operation
- 66 to 185 mV/A output sensitivity
- Output voltage proportional to AC or DC currents
- Factory-trimmed for accuracy
- Extremely stable output offset voltage
- Nearly zero magnetic hysteresis
- Ratiometric output from supply voltage
Current Sensor ACS712 20AMPS
- Supply Voltage: 4.5V ~ 5.5V DC
- Measure Current Range: 20A
- Sensitivity: 100mV/A
- The low-noise analogue signal path
- Device bandwidth is set via the new FILTER pin
- 5 µs output rise time in response to step input current
- Small footprint, low-profile SOIC8 package
- 1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8
- Small footprint, low-profile SOIC8 package
- 1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8
- Output voltage proportional to AC or DC currents
- Factory-trimmed for accuracy
- Extremely stable output offset voltage
- Nearly zero magnetic hysteresis
- The ratiometric output from the supply voltage.
CURRENT SENSOR ACS712 30AMPS
- Current sensor chip: ACS712ELC-30A
- Supply voltage: 4.5V to 5.5V DC
- Current range: -30A to 30A
- Sensitivity: 66 millivolt/ampere
- Low noise analogue signal path
- Output rise time: 5 micro sec
- Extremely stable output offset voltage
- Zero magnetic hysteresis
- Factory trimmed for accuracy
- Easy to interface with a microcontroller, since it outputs an analogue voltage
- Onboard power indicator
- Dimension: 7*5*5cm
- Weight: 400gm
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews