LOAD CELL 5Kg
₹500.00 Original price was: ₹500.00.₹450.00Current price is: ₹450.00. inc. GST
- Capacity: 5Kg
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals(N max): 2000
- Minimum number of load cell verification intervals(Vmin): E Max/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(O): 402±6
- Output resistance(O): 350±3
- Insulation resistance(MO<50V>): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2*350mm
- Dimensions :3.45 x 2.4 x 0.9 inches
- weight:25gm
A load cell transducer/sensor creates an electrical signal whose magnitude is directly proportional to the force measured. The various types of load cells include hydraulic load cells, pneumatic load cells, and strain gauge load cells. The standard straight bar load cell 5kg(sometimes called a strain gauge) translates up to 5 kg of pressure (force) into an electrical signal. Each load cell 5kg measures the electrical resistance that changes is proportional to the strain (e.g. pressure or force) applied to the bar. The output of the load cell is in milli-volts and cannot be directly measured by a micro-controller. So an ADC with high resolution or an instrumentation amplifier reads the output of the load cell to the microcontroller.
The intensity of deformity defines how much force applied, and this value digitally sent to an interface module. This gauge can determine how heavy an object is, whether the object’s weight changes over time or if you simply need to sense the object by measuring strain or load applied to a surface. This straight bar load cell made from an aluminum alloy. And it is capable of reading a capacity of 5KG of weight. These load cells also provide an IP66 protection rating for the sensor.
A load cell has four lead wires which connect HX711 A/D Pressure Sensor. It is easy to use with a driving voltage of 5-10V and produces the output voltage as the force changes.
Due to its high accuracy, it has a wide range of applications in the electronic platform scale, Digital scale, etc

Related products
1Kg Load cell Electronic Weighing Scale Sensor
- Capacity: 1KG
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals(N max): 2000
- Minimum number of load cell verification intervals(Vmin): E Max/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(O): 402±6
- Output resistance(O): 350±3
- Insulation resistance(MO<50V>): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2*350mm
- Dimensions :Â 10.92 x 9.52 x 0.51 cm
- weight:10gm
5pcs x NFC Sticker tags 13.56MHz ISO14443A 25mm Ntag213 RFID NFC tag
- Chip: Ntag213.
- Physical capacity: 180 bytes.
- Usable capacity: 144 bytes.
- Protocol: ISO14443A.
- Working frequency: 13.56 MHZ.
- Reading and writing distance: 1 to 5 cm.
- Reading and writing time: 1 to 2 ms.
- Working temperature: -20 to 55 degrees, the humidity of 90%.
- Erase times : > 100000 times.
- Data storage: > 10 years.
- Reading time: 100000 times.
- Diameter: 25mm.
- Materials: PE self-adhesive + coated paper.
- Manufacturer programmed 7-byte UID for each device
- Preprogrammed Capability container with one-time programmable bits
- Field programmable read-only locking function
- ECC-based originality signature
- 32-bit password protection to prevent unauthorized memory operations
- NFC Forum Tag 2 Type compliance
5V-12V ZVS Induction Low Voltage Heating Power Supply Module Board + Coil
Acrylic case for XH-W1209 temperature controller
Afr-2000 G1/4” Air Compressor Water Filter with Regulator Air Tool Cleaning
- Model: AFR2000 (AFR is the model, 2000 refers to the port size)
- Operating Fluid: Air
- Joint pipe bore: G 1/4"
- Range of Adjustable Pressure: 0.05-0.99 MPa
- Adjustable Pressure: 0.99 MPa
- Ensured Pressure Resistance: 1.5 MPa
- Operating Temperature Range: 5℃-60℃
- Filter Grade: 40 µ
- Capacity of Body: 15 cc
- Gauge caliber: G1 / 8
- Material: Metal, plastic
- Discharge water automatically
- Lightweight, small size, easy installation, and maintenance
- No matter the size of the inlet pressure and flow fluctuations, always maintain a stable outlet pressure
- Dimension: 6.29 x 2.75 x 2.75 inch
LOAD CELL 10 Kg
- Capacity: 10Kg
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals(N max): 2000
- Minimum number of load cell verification intervals(Vmin): E Max/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(O): 402±6
- Output resistance(O): 350±3
- Insulation resistance(MO<50V>): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2*350mm
- Dimensions : 15.9 x 14.1 x 2.7 cm
- weight: 190gm
RFID Tag Key Fob Keyfobs 125Khz
- Material: ABS
- Response Frequency: 125Khz
- 2kbps ASK
- Diameter: ~29mm
- Range: 0-10 cm
- Manchester encoding
- 32-bit unique ID
- Uses TK4100 chip which is compatible with EM4100
- 64-bit data stream [Header+ID+Data+Parity]
- Read Time: 1-2ms
- Operating Temperature: -20c ~ 85 degree C
- Endurance:> 100,000 times
- 64-bit data stream [Header+ID+Data+Parity]
- Designed for the RFID 125KHZ duplicator. can copy all the ID card, such as Access Card, District Card, Parking etc
- Dimension: 43.7×30.5×5.3mm
UNI T Infrared Thermometer UT30R
- Measurement range: 32 to 45 ° C.
- Resolution: 0.1 ° C.
- Test distance: 5-10 cm
- Accuracy : ± 0.3°C
- Measurement repeatability : 0.3°C
- Response time : 500 ms
- Optical measuring range : 5.5μm ~ 14.0μm
- Simple, fast and accurate IR thermometer
- Flashing arm at high temperature (more than 37.2 ° C)
- Single button operation
- LCD display with backlight for dark condition
- Auto data hold for 8s
- Â Auto power off
- Low voltage indication
- Option of Celsius/Fahrenheit
- Power-off memory function