- Operating voltage:3.3V/5V
- Sensitivity: Adjustable via a potentiometer
- Input Signal: Resistance, NOT Conductivity
- Output Signal: Voltage, analogue reading
- Finger contact material: Nickel
- Detects conductance of the skin
- Finger Straps for electrodes
GSR is referred to as galvanic skin response, a prominent method in the electronics field used for measuring the electrical conductance of the skin. Basically, Strong emotion can cause a stimulus to your sympathetic nervous system. This results in more sweat being secreted by the sweat glands. Grove – GSR sensor capable of spotting such strong emotions by simply attaching two electrodes to two fingers on one hand. It is quite interesting to create emotion-related projects like sleep quality monitor. And also widely used in some galvanic skin response devices such as lie detectors.
In order to measure GSR, we take advantage of the electrical properties of the skin. Normally the skin resistance varies with respect to sweat gland activity. So the greater sweat gland activity, the more perspiration, and thus, less skin resistance. GSR signal does not measure resistance, but conductance. Conductance is the opposite of resistance and is measured in siemens (Conductance = 1 / Resistance). Thus the conductance makes the signal interpretation easier, since the greater the sweat gland activity, the higher the skin conductance.
By simply applying a constant voltage of usually 0.5 V to the two electrodes that are in contact with the skin, the conductance can be determined. The circuit also contains minimal resistance compared to the skin resistance that is in series with the voltage supplier and the electrodes. As the voltage (V) is kept constant, skin conductance (C) is calculated by measuring the current (I) flow through the electrodes.

Related products
DHT11 Sensor
DS18B20 MODULE
- Resolution: 9bits to 12bits (Selectable)
- Supply Voltage (V): 3 to 5.5
- Temperature Range(°C): -55 to +125
- Measuring Accuracy(°C): ±0.5
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into the chip
- Multiple sensors can share one pin
- Maximum conversion time and response: 750 ms
- Multidrop capability simplifies distributed temperature sensing applications
- Requires no external components
- Digital signal output
- 18B20 Temperature Sensor Chip
- Send data via a pin
- User-definable nonvolatile (NV) alarm settings
- Dimension: 19*15*6cm
- Weight: 9gm
Eye Blinking Sensor
Induction Cooker Sensor
LDR SENSOR 20mm
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- -Â Â Â Ambient temperature : -20 ~ +55
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 95% RH
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Environmental oxygen content: 21%
- Storage conditions :
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Temperature : -20 ~ +70
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm