I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
₹250.00 Original price was: ₹250.00.₹200.00Current price is: ₹200.00. inc. GST
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
A GAS sensor or a GAS Detector defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. A gas sensor is a simple drive circuit that interacts with gas to measure concentration. MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module is ideal for detection of Carbon Monoxide and Methane Gas in the air such as portable gas detectors or in other industrial applications. Carbon Monoxide is a toxic, colorless, odorless, flammable gas that is slightly less dense than air.MQ9 is a Tin oxide semiconductor sensor designed explicitly for Carbon Monoxide (CO) concentration detection. It offers very good sensitivity and a fast response time. MQ9 Gas sensor measures CO concentrations providing lower conductivity in clean air.MQ9 works by detecting the CO concentration of cycle high and low temperature, and detect CO at low temperature (heated by 1.5V).
An analog resistive output provided by the sensor with conductivity higher along with the gas concentration rising. The resistance varies inside the sensor on the detection of carbon monoxide. Under the high temperature (heated by 5.0V),  it detects Methane, Propane, combustible gas, etc, and the other gases adsorbed under the low temperature are cleared. We just need to power the heater coil with 5V, add a load resistance. As a result, the sensor and load resistor in the module form a potential divider and connect the output to an ADC or a simple OPAMP comparator. Thus the CO content detected by measuring this resistance. Therefore the lower the sensor resistance, the upper the voltage reading is going to be. MQ9 sensor designed to operate at temperatures ranging from -10 to 50°C. And consumes less than 150 mA current at 5 V.
Applications of MQ9 CO Gas Sensor:
- Domestic gas leakage detector
- Industrial CO detector
- Portable gas detector

Related products
1 CHANNEL 12V RELAY
- 1-Channel relay interface board
- Operating voltage: 12V DC
- Provide high current relay of 15A
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances
- LED status indicates relay ON/OFF state.
- High current relay of 10A @250 V AC/10A@ 30V DC
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 43*17*17mm
- Weight: 150gm
1 CHANNEL 5V RELAY
- 1 channel relay board
- Operating voltage: 5V
- Maximum current: 2 A
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- configured as SINGLE POLE DOUBLE THROW( SPDT)
- LED status indicates relay ON/OFF state.
- Standard TTL level logic controlled
- One normally closed and one normally opened contact
- Compatible with any 5V microcontroller
- Dimension: 43*17*17mm
- Weight: 150gm
BMP280 Pressure Sensor module High Precision Arduino
- Chip:BMP280
- Operating Voltage: 1.71V to 3.6V
- Communication method: Standard IIC/SPI communication protocol
- Pin pitch: 2.54mm
- Operating Temperature: -40 to +85 deg. Celsius
- Operating Pressure: 300 hPa to 1100 hPa
- Peak current: 1.12mA
- Current consumption: 2.7µA @ 1 Hz sampling rate
- Accuracy between( 700 to 900hPa and 25 to 40 deg. C): ±0.12hPa and ±1.0m
- Package 8-pin LGA metal-lid
- Relative accuracy(950 … 1050hPa @25°C): ±0.12 hPa, equiv. to ±1 m
- RoHS compliant, halogen-fre
- Module size: 11.5mm*15mm
Induction Cooker Sensor
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes