- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.Â
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
The  MQ-5 Methane LPG Liquid Propane Gas Sensor Module is based on the MQ5 sensor IC as a gas sensing element. MQ-5sensor is ideal for detection or measuring of LPG, natural Gas & Town Gas at a range of 200-10000ppm. It offers very good sensitivity and fast response to LPG and also shows a small sensitivity to alcohol & smoke. It offers a wide range of applications in gas leakage detecting equipment in consumer and industry applications The module comes with basic components integrated allowing the sensor to function properly. And interfaced easily to any controller as the user prefers. Hence no external components are required, we need to just plug in Vcc & ground pins and you are ready to go.
MQ5 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON. As a result, the digital pin will go from logic high to logic low 0V. The presence of onboard LM393 comparator IC compares the adjustable preset value and also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low. MQ5Â gas sensor module can be easily interfaced to any Microcontroller, Arduino, or even Raspberry Pi.
While using the analogue pin to measure PPM, the TTL drove (0-5V) analogue pins read values using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
1 CHANNEL 12V RELAY
- 1-Channel relay interface board
- Operating voltage: 12V DC
- Provide high current relay of 15A
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances
- LED status indicates relay ON/OFF state.
- High current relay of 10A @250 V AC/10A@ 30V DC
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 43*17*17mm
- Weight: 150gm
8 CHANNEL 5V RELAY
- Relay operating voltage: 5V
- 8 channel
- High impedance controller pin
- One normally closed contact and one normally opened
- Useful for appliances control
- Power supply indicator and control indicator lamp
- Pull-down circuit to avoid malfunction
- Can control both DC and AC to 220v AC load
- Works with both 3.3 V and 5 V logic with the less current drive
- 3 terminals per SPDT relay
- Standard interface can be directly controlled by a microcontroller like Arduino, 8051, AVR, PIC, DSP, ARM, MSP430, TTL logic
- Dimension: 7*6.4*1 inch
BMP280 Pressure Sensor module High Precision Arduino
- Chip:BMP280
- Operating Voltage: 1.71V to 3.6V
- Communication method: Standard IIC/SPI communication protocol
- Pin pitch: 2.54mm
- Operating Temperature: -40 to +85 deg. Celsius
- Operating Pressure: 300 hPa to 1100 hPa
- Peak current: 1.12mA
- Current consumption: 2.7µA @ 1 Hz sampling rate
- Accuracy between( 700 to 900hPa and 25 to 40 deg. C): ±0.12hPa and ±1.0m
- Package 8-pin LGA metal-lid
- Relative accuracy(950 … 1050hPa @25°C): ±0.12 hPa, equiv. to ±1 m
- RoHS compliant, halogen-fre
- Module size: 11.5mm*15mm
Induction Cooker Sensor
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ4 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- DOUT: TTL output
- AOUT: Analog output
- Detection Gas: Natural gas/Methane
- Detection range: 300 to 10000ppm
- Digital Out is High or Low based on an adjustable preset threshold,
- Stable & Long Life.
- Onboard Power indication
- Standard Encapsulation Bakelite, Metal cap
- Good sensitivity to Combustible gas in a wide range
- High sensitivity to CH4, Natural gas.
- Small sensitivity to alcohol, smoke.
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap