I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ8 Module
₹250.00 Original price was: ₹250.00.₹175.00Current price is: ₹175.00. inc. GST
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Dual signal output (analogue output, and TTL level output)
- Detection Gas: Hydrogen
- Detection range: 100 to 10, 000 ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller)
- Onboard Power indication
- Good sensitivity to Combustible gas in a wide range
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference.
- Simple drive circuit
- An indication of the signal output
- High sensitivity to hydrogen.
- The higher the voltage, the concentration of the analogue output voltage is higher.
- Four screw holes for easy positioning
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
This is based on the MQ-8 H2 sensor IC with Hydrogen as a gas sensing element. MQ-8 sensor is ideal for the detection or measuring hydrogen concentration at a range from 100 to 10, 000 ppm in air. It offers excellent sensitivity and fast response to H2 and also shows also has anti-interference to other gases. This makes it ideal for portable gas detectors or in other industrial applications. The module comes with basic components integrated allowing the sensor to function properly. And interfaced easily to any controller as the user prefers. Hence no external components are required, we need to just plug in Vcc & ground pins and you are ready to go.
MQ8 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON. As a result, the digital pin will go from logic high to logic low 0V. The presence of onboard LM393 comparator IC compares the adjustable preset value and also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low.
While using the analogue pin to measure PPM, the TTL drove (0-5V) analogue pins read values using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. Thus the H2 content was detected by measuring this resistance. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
1 CHANNEL 5V RELAY
- 1 channel relay board
- Operating voltage: 5V
- Maximum current: 2 A
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- configured as SINGLE POLE DOUBLE THROW( SPDT)
- LED status indicates relay ON/OFF state.
- Standard TTL level logic controlled
- One normally closed and one normally opened contact
- Compatible with any 5V microcontroller
- Dimension: 43*17*17mm
- Weight: 150gm
16 CHANNEL 5V RELAY
- 16 channel 5V relay board
- Operating voltage: 5V
- Supply current: 500mA
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- Optocoupler protection
- Low state voltage: 0V to 0.5V (relay is ON)
- High state voltage: 3.7V to 5V(relay is OFF)
- Single-chip design with reliable performance
- Strong anti-interferences
- Strong anti-jamming ability and stable performance
- The on-board power supply module doesn’t need any external power
- Common terminal(com) in each rely is user friendly and can be accessed by different signal
- Dimension: 180*90*20mm
- Weight: 100gm
4 CHANNEL 12V RELAY
- 4-Channel relay interface board
- Relay input voltage: 12V DC
- Relay output: 5A/250V AC
- Signal input:5V DC from the microcontroller
- High current relay of 10A @250 V AC/10A@ 30V DC
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances such as DC motors, solenoid valves, lamps, etc.
- LED status indicates relay ON/OFF state.
- Power battery terminal for relay output and aux power connection
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- Relay can directly control all equipment’s and loads
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 165*65*1mm
- Weight: 7gm
4*3 MATRIX KEYPAD
- Operating voltage: 12V DC
- The maximum voltage across each button: 24v
- The maximum current across each button: 3mA
- Ultra-thin design
- Adhesive backing provides easy integration
- Easy communication with any microcontroller
- Flexible
- Only 7 microcontroller pins required to access 12 keys
- High price-performance ratio
- Allows microcontroller to scan 8 output pins to check which 16 button
- Long life
- Maximum operating temperature: 0 degrees to 50 degrees Celsius
- Dimension: 70*77*1mm
- Weight: 7.5gm
4*4 MATRIX KEYPAD
- The maximum current across each button: 3mA
- Easy communication with any microcontroller
- Ultra-thin design
- Adhesive backing provides easy integration
- High price-performance ratio
- Allows microcontroller to scan 8 output pins to check which 16 button
- Long life
- Maximum operating temperature: 0 degrees to 50 degrees Celsius
- Dimension: 70*77*1mm
- Weight: 7.5gm
DC POWER SUPPLY MODULE FOR DC ADAPTER PLATE
DC-DC BOOST MODULE 0.9V-5V/5V 600MA USB MOBILE Power Supply Module
- Ultra-compact PFM chip
- Module properties: nonisolated step-up module
- Input voltage: 1v-5v
- Output voltage: 5.1v-5.2V
- Output current: rated 1A-1.5A
- Efficiency: 96%
- Output ripple: 30mv for 20M bandwidth
- Switching frequency: 500khz
- Voltage indication for led lights with load( for less than 2.7v led indicator off)
- Operating temperature:-40 degrees to 85 degrees Celsius
- Full load temperature rise: 30 degrees Celsius
- Quiescent current: 130ua
- Load regulation: +/-1%
- Voltage regulation: +/-0.5%
- Dynamic response speed: 5% 200Us
- Short circuit protection
- Reverse polarity protection
- Dimension: 2.5*1.8*1.8gm
- Weight: 400gm
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.