I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ2 Sensor
₹200.00 Original price was: ₹200.00.₹150.00Current price is: ₹150.00. inc. GST
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ2 sensor also known as Chemiresistor ideal for detection or measuring of LPG, Alcohol, Propane, Hydrogen, CO, and even methane. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality monitors and gas leakage alarm systems. The MQ2 sensor operates at a voltage of 5V DC and draws around 800mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ2 sensor is a Tin oxide semiconductor sensor designed with higher sensitivity to liquefied petroleum gas, propane, hydrogen, and other combustible vapours. It detects gases anywhere in a range from 200 to 10000ppm. This sensor can detect gas either by digital pin or by analogue pin. The digital low signal light is accessed through the IO ports on the Microcontroller. The analogue output is a concentration, i.e. increasing voltage is directly proportional to increasing concentration. By using the external load resistance the resistance variation is converted into a suitable voltage variation. A small potentiometer in this sensor permits the adjustment of the sensitivity of the sensor circuit. This sensor features long life, low cost, and reliable stability make it particularly suitable for Air quality monitoring applications.
MQ2 sensors are enclosed in two-layer stainless steel that provides an Anti Explosion Network. This is enclosed in order to avoid the heater element explosion, as we are sensing flammable gases. It also provides protection for the sensor and filters out suspended particles so that only gaseous elements pass through the chamber.
Applications:
- Detects or measure Gases like LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Air quality monitor
- Gas leak alarm
- Safety standard maintenance
- Maintaining environmental standards in hospitals

Related products
DHT11 Sensor
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
Force Sensor 14.7MM
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
LDR SENSOR 20mm
MQ5 Module
- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews
There are no reviews yet.