Showing 745–756 of 3359 resultsSorted by average rating

Delta Chrome II DIN Rail Power Supply (DRC Series)

Model Output Voltage Output Power / Current Input Voltage Other specs
DRC-24V030W1RZ 24 V 30 W (≈1.5 A) RS Components+1 85-264 V AC DIN-rail, class II
DRC-24V100W1RZ 24 V ~100 W (3.83 A) DeltaPSU+1 85-264 V AC compact size
DRC-24V100W1AZ 24 V 91.2 W (3.8 A) DeltaPSU 90-264 V AC 91 × 89.9 × 55.6 mm size
Others: 15 W model, 12 V output, 48 V output variants.

Delta CliQ II series DIN rail power supplies

📋 Example Specification (model DRP024V480W1BA)

Here’s a detailed breakdown for one model in the series (24 V, 480 W) to illustrate what you can expect; use this as a baseline for other models (like the 48 V / 240 W one). deltapsu.com+1

Parameter Value
Output voltage 24 Vdc deltapsu.com
Output current 20 A deltapsu.com
Output power 480 W deltapsu.com+1
Input voltage range 85–264 Vac, or 120–375 Vdc Mouser Electronics+1
Efficiency > 91% @ 115 Vac, > 92% @ 230 Vac (for this model) deltapsu.com
Dimensions (H × W × D) 121 mm × 144 mm × 118.6 mm deltapsu.com
Unit weight 1.37 kg deltapsu.com
Operating temperature –25 °C to +75 °C (cold start to –40 °C) deltapsu.com
Protection / Certifications Over-voltage, over-current, over-temperature protections; SELV output; ATEX/Class I Div 2 variant available. deltapsu.com+1

Delta PMT‑2 Series SMPS

📋 Typical Specifications (example model)

Using the model PMT-12V100W2BA as a reference: deltapsu.com+1

  • Output Voltage: 12 V

  • Output Current: 8.5 A

  • Output Power: ~102 W

  • Output Voltage Adjustment Range: ~10.8 – 13.2 V

  • Input Voltage Range: 90 – 264 Vac

  • Efficiency: ~87.5% typ. @ 230 Vac

  • Hold-up time: ~42 ms @ 230 Vac

  • Ripple / Noise: <120 mVpp (0 °C to 70 °C)

  • Dimensions: 129 × 97 × 30 mm

  • Weight: ~0.285 kg

  • MTBF: >700,000 hrs (Telcordia SR-332)

  • Protections: Short circuit (hiccup, non-latching), Overload/Overcurrent (auto recovery), Over-temperature (latch)

Another example: PMT-24V350W2BR (higher power version) gives ~350.4 W, 24 V output, 14.6 A current, selectable input 90-132 / 180-264 Vac, dimensions 215×115×30 mm.

Cold Room Electrical Panel

 

Input Voltage: 230V/415V AC

  • Compatible Systems: Single-phase or three-phase cold room setups

  • Controller Options: Digital thermostat, PID controller, or programmable controller

  • Protection Devices: OLR, MCB/MCCB, phase preventer, HP/LP switch

  • Load Handling: Suitable for 1 HP to 10 HP compressors (customizable)

  • Cooling System Control: Compressor, evaporator fan, condenser fan

  • Indicators: Power ON, compressor ON, fan ON, fault alerts

  • Enclosure Type: MS/SS enclosure with IP-rated protection

  • Customization: Available as per cold room size and compressor rating


Applications

  • Cold storage rooms

  • Meat, fish, dairy & vegetable storage

  • Pharmaceutical storage chambers

  • Food processing units

  • Commercial refrigeration systems

Subzero SZ-7510P Digital Temperature Controller

Key Features

  • Accurate digital temperature monitoring and control

  • Supports multiple sensor types for versatile applications

  • Clear LED display for easy reading

  • User-friendly programming and adjustable set points

  • Compact, durable design suitable for industrial use

  • Overload and temperature protection functions

  • Ideal for HVAC, refrigeration, cold rooms, and automation equipment

Rope Safety Switch

Rope Safety Switch

A reliable emergency stop switch designed to immediately halt machinery through a pull-rope mechanism, ensuring maximum safety in industrial environments.

CS AR series with actuator

Key Features

  • Integrated Actuator System for precise linear or rotary motion

  • High Torque & Excellent Load Handling for industrial-grade performance

  • Durable Build Quality designed to withstand continuous operation

  • Smooth & Accurate Positioning with minimal backlash

  • Compact & Efficient Design for easy installation

  • Low Maintenance with long service life

  • Compatible with Various Automation Systems for flexible use

  • Reliable Performance under demanding environmental conditions

Solenoid door lock switches

Brand :      Pizzato

Solenoid Door Lock Switches

Pizzato solenoid door lock switches provide reliable safety locking for industrial machines and access doors.

FY/YG Series – Standard Solenoid Locks

The FY/YG Series offers robust, standard solenoid door lock switches with high holding force, durable construction, and multiple actuator options. Ideal for general machine safety and guard locking applications.

NG/NS Series – RFID-Type Switches

The NG/NS Series features advanced RFID-based safety switches with an integrated RFID door handle for maximum tamper resistance and secure access control. Designed for high-risk and automated industrial environments.

Digital Time Switches

Digital time switches with programmable scheduling for automatic control of lights, pumps, and electrical appliances.

Sequential/Combination Timers S-Series – Precision Timing Made Simple

Features
  • Hold /Restart - User Selectable.
  • The program of the first relay can be copied to all remaining relays or individually programmed for each relay
  • Non-potential pulse start signal for initiation. (Refer Note 3)
  • single/repeat cycle (Refer Note 1), Time inhibit / Pause & Cascading of units are available (Refer Note 5).
Applications
  • Bag Filter systems, Dust pollution systems, Air handling systems, MCC panels, Pneumatic Conveyors, Process Industries

Maximum Demand Meters (EMS Series)

Key Features:

  • Measures maximum demand accurately over defined intervals

  • Supports single and three-phase systems

  • High-brightness digital display for clear readings

  • Data logging and real-time monitoring

  • Easy installation and configuration

  • Suitable for industrial and commercial environments

Applications:

  • Industrial power monitoring

  • Commercial energy management

  • Utility metering and analysis

  • Load optimization and control

Single Phase Preventor Monitoring Device

Technical Specifications:

  • Input Voltage: 230V AC (Single Phase)

  • Frequency: 50/60Hz

  • Mounting Type: DIN Rail / Panel Mount

  • Output Contact: 1 C/O Relay

  • Operating Temperature: –10°C to +55°C

Applications:

  • Industrial control panels

  • Water pumps and compressors

  • HVAC systems

  • Agricultural motors and machinery

Maintain uninterrupted performance and protect your valuable equipment with this reliable Single Phase Preventor Monitoring Device — a must-have for efficient and safe electrical operations.