I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Electricity Failure Alarm
₹1,750.00 Original price was: ₹1,750.00.₹1,500.00Current price is: ₹1,500.00. inc. GST
- Conversion time : 0.5 seconds
- Monitoring voltage : AC150V-400V /50 to 60Hz
- Alarm volume :110-120 dB
- Usage: Alarm connected to AC 220V (or AC 380V) power supply, turn the power switch to enter the working state
This Electricity Failure Alarm designed as a power supply monitoring device that will trigger a buzzer when the mains supply cuts off. At the same time, the light-emitting diode will be turned ON. This device function to inform the loss of power supply to some critical installation such as pump in fish tank. When the buzzer sounds, you’ll know there’s been a power outage. And steps must be made to correct the issue, such as supplying other power or moving the facility.
The circuit comprises mostly of an AC relay. Use a 120V AC relay if the mains input is 120V AC. Use a 240V AC relay if the mains input is 240V AC. The relay is a Single Pole Double Throw (SPDT) type, and if it is not powered, the COM will be connected to the NC terminal. The COM terminal will be linked to the NO terminal once it has been activated.
This sort of relay may be found at almost any electronics store. Ensure that the coil of the relay is rated for the power supply you’re using. The relay will be damaged or will simply not operate if the rating is incorrect, even if it is correctly connected to the mains supply. When connecting the mains to the relay, use extreme caution. Before connecting the relay, make sure you take the required precautions, such as isolating the mains.

Related products
6-30V 1-Channel Power Relay Module with Adjustable Timing Cycle
- Operating voltage: 6 - 30V DC
- 1 Channel delay trigerred relay module
- Delay time: 0.1 second ~ 999 minutes
- Seven Segment Display
- Operating voltage: DC 6V-30V (supports micro USB 5V power supply)
- Trigger signal source: high-level trigger (3V-24V) signal ground and system to improve the system's anti-jamming capability (also short-circuit altogether)
- Output capability: it can control the device within DC 30V 5A or within AC 220V 5A
- Quiescent current: 20mA
- Operating current: 50mA
- Service life: more than 100,000 times
- Working temperature: -40°C-85°C
- With optocoupler isolation, enhanced anti-jamming capability, industrial grade circuit board, set parameters for memory after power failure.
- Dimension: 6.2 * 3.8 * 1.7cm
E27 PIR Infrared Motion Sensor LED Light Lamp Holder Control Switch
ESP8266-12E 10A 220V NETWORK RELAY WIFI MODULE INPUT DC 7V-30V
- Input voltage: DC 7V-30V
- Relay voltage: 220V
- Relay current: 10A
- ISM: 2.4GHz
- PA: +25dBm
- Input over-voltage protection
- Input overcurrent protection
- ESP8266 WIFI module with 4 layered board design
- LED indicator for input status and output status
- 220V 10A relay, normally opened, and one normally closed
- Optocoupler isolation input, TVS input protection
- Access server control via HTTP protocol by TCP client mode, high current terminals
- Dimension: 65*40*18mm
Fan Wifi Controller
KSEB FAILURE ALARM
KX931 Travel Plug
SWIVEL INFRARED MOTION SENSOR OCCUPANCY SWITCH
- Power frequency: 50~60Hz
- Control light: <3 LUX ~ 2000 Lux (Adjustable)
- Time-Delay: Minimum:8sec±3sec to a Maximum:7min±2min
- Power source: 100V/AC-130V/AC <=> 220V/AC-240V/AC
- 1200W(220V/AC-240V/AC) - 800W(100V/AC-130V/AC)
- Power consumption:0.45W(static 0.1W)
- Detection range: 180°
- Detection distance: 12 meters maximum at less than 24°C
- Working temperature:-20 to 40°C
- Working humidity: Less than 93% Relative Humidity
- Suggested Installation height: 0.5 meter to 3.5 meters
- Detection motion speed: 0.6 to 1.5 meters per second
- Identify day and night automatically -
- Power and detection indication
- Time-delay added continually
- Time-delay adjustment according to the customer desire. The minimum time is 8sec±3sec and the maximum is 7min±2min.
- Locking function: the sensor will keep load lighting when power is shut off for 2 seconds and then on. When power is shut off for 4 seconds and then on, sensor will resume automation.
Wall Mount Sound Security Light Delay Sensor Control Lamp Switch Ac 220V
- Operating voltage: 220v
- Load Power: 30w
- Sound Control Sensitivity: 95db- 75db
- Light Control Induction: 6lux
- Delay Time: 30 seconds
- High-quality Energy Saving Auto Switch Controlled by Light and Sound
- Ideal Light Switch for use around bathroom, hallways, staircases and porches
- Easy to install
- Load Type: Control energy-saving lamps under 80W,incandescent under 60W,LED light under 30W
- Installation: Shut off the power, load must not short-circuit
- Light ON automatically when sound is detected in the dark, when in daytime or under strong light, circuit in the off state and the light does not turn on.
- Dimension: 6 X 5 x 2.6Cm

Reviews