- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
GP2Y1010AU0F sensor also known as optical air quality sensor used to Sense Dust Particles. This compact-sized optical sensor consists of works by detecting the reflected light of dust in the air. It is an ideal solution to detect very fine particles like cigarette smoke. Moreover, it also determines the smoke from house dust by pulse pattern of output voltage, thus commonly used in air purifier systems. The sensor features very low current consumption (20mA max, 11mA typical), and can be powered with up to 7VDC. The output of the sensor is an analogue voltage proportional to the measured dust density, with a sensitivity of 0.5V/0.1mg/m3. GP2Y1010AU0F sensor operates at a voltage range of 4.5V to a maximum of 5.5V DC supply voltage.
GP2Y1010AU0F dust sensor consists of an infrared emitting diode and a phototransistor diagonally arranged into this device system. This works on the principle of Laser Scattering. Therefore the Infrared emitting diode in the sensor illuminates the particles in the air that enters through the air inlet. And this scattered light is transformed into a form of the signal by a phototransistor. Further, the amplifier circuit amplifies these signals and is then processed to obtain the particle concentration. The intensity of the scattered light depends on the dust particles.
The more the dust particles in the air, the greater will be the intensity of light. Thus the Output voltage at the VOUT pin of the sensor varies according to the intensity of scattered light. Moreover, this module offers a wide range of applications in dust removal equipment alarm equipment, air purification equipment, dust robots, fire alarm, etc.

Related products
BMP 180 Digital Barometric Pressure Sensor
BMP280 Pressure Sensor module High Precision Arduino
- Chip:BMP280
- Operating Voltage: 1.71V to 3.6V
- Communication method: Standard IIC/SPI communication protocol
- Pin pitch: 2.54mm
- Operating Temperature: -40 to +85 deg. Celsius
- Operating Pressure: 300 hPa to 1100 hPa
- Peak current: 1.12mA
- Current consumption: 2.7µA @ 1 Hz sampling rate
- Accuracy between( 700 to 900hPa and 25 to 40 deg. C): ±0.12hPa and ±1.0m
- Package 8-pin LGA metal-lid
- Relative accuracy(950 … 1050hPa @25°C): ±0.12 hPa, equiv. to ±1 m
- RoHS compliant, halogen-fre
- Module size: 11.5mm*15mm
DS18B20 MODULE
- Resolution: 9bits to 12bits (Selectable)
- Supply Voltage (V): 3 to 5.5
- Temperature Range(°C): -55 to +125
- Measuring Accuracy(°C): ±0.5
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into the chip
- Multiple sensors can share one pin
- Maximum conversion time and response: 750 ms
- Multidrop capability simplifies distributed temperature sensing applications
- Requires no external components
- Digital signal output
- 18B20 Temperature Sensor Chip
- Send data via a pin
- User-definable nonvolatile (NV) alarm settings
- Dimension: 19*15*6cm
- Weight: 9gm
GSR Sensor for Grove
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ5 Module
- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.Â
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
Thermostat Sensor 110D
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant