I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ2 module
₹250.00 Original price was: ₹250.00.₹175.00Current price is: ₹175.00. inc. GST
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 300 -10000 ppm
- Sensitive to H2, LPG, CH4, CO, Alcohol, Smoke or Propane,
- Digital Out is High or Low based on an adjustable preset threshold,
- High Sensitivity to Smoke & combustible gasses like Hydrogen, LPG & Propane.
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
The MQ-2 sensor module is based on the MQ2 sensor that provides a lower conductivity to clean the air as a gas sensing material. MQ2 sensor is ideal for detection or measuring of LPG, Alcohol, Propane, Hydrogen, CO, and even methane. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality monitoring and gas leakage types of equipment. When the sensor is kept in the environment, the conductivity increases with respect to the rise in the concentration of gases. The module comes with basic components integrated allowing the sensor to function properly. And can be interfaced easily to any controller as the user prefers. The MQ2 air monitoring sensor module operates at a voltage of 5V.
MQ2 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON and the digital pin will go from logic high to logic low 0V. LM393 Op-Amp Comparator IC was used to compare the actual gas value with the value set using the potentiometer. The presence of onboard LM393 comparator IC in the MQ2 module also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low.
While using the analogue pin, the analogue values (0-5V) read using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
16 CHANNEL 5V RELAY
- 16 channel 5V relay board
- Operating voltage: 5V
- Supply current: 500mA
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- Optocoupler protection
- Low state voltage: 0V to 0.5V (relay is ON)
- High state voltage: 3.7V to 5V(relay is OFF)
- Single-chip design with reliable performance
- Strong anti-interferences
- Strong anti-jamming ability and stable performance
- The on-board power supply module doesn’t need any external power
- Common terminal(com) in each rely is user friendly and can be accessed by different signal
- Dimension: 180*90*20mm
- Weight: 100gm
2 CHANNEL 5V RELAY
- High current relay
- Two LED S to indicate relays ON/OFF status
- Low-level trigger expansion board
- Opto isolation circuitry
- Works with logic level signal 3.3V or 5V devices
- Can be used as normally open (NO) or normally closed (NC)
- Back EMF protection
- Ensures diode current protection
- AC control voltage: 250v @mx10A
- DC control voltage: 30V @max 10A
- Easy installation and fixing
3.3V/5V MB102 Breadboard Power Supply Module
- Input voltage: 6.5V to 12V
- Output voltage: 3.3V to 5V
- Output current: 700Ma
- Apply to MB102 breadboard
- Sorting jumpers used to switch voltage between 3.3V and 5V
- Onboard LED indicator to show the presence of power
- Short circuit protection
- Fits securely on standard 400 and 830 points on the breadboard
- Dimensions: 53*32*23mm
- Weight: 10gm
4 CHANNEL 12V RELAY
- 4-Channel relay interface board
- Relay input voltage: 12V DC
- Relay output: 5A/250V AC
- Signal input:5V DC from the microcontroller
- High current relay of 10A @250 V AC/10A@ 30V DC
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances such as DC motors, solenoid valves, lamps, etc.
- LED status indicates relay ON/OFF state.
- Power battery terminal for relay output and aux power connection
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- Relay can directly control all equipment’s and loads
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 165*65*1mm
- Weight: 7gm
4 CHANNEL 5V RELAY
- 4-Channel relay interface board
- Operating voltage range: 3.3V to5V
- Maximum current: 10A
- Supply current: 20 mA
- High current relay of 10A @250 V AC/10A@ 30V DC
- Control signal: TTL level
- For quick and easy connection high-quality screw terminals provided
- Pull-down circuit to avoid malfunction
- Power supply indicator
- Can control both AC & DC appliances such as DC motors, solenoid valves, lamps, etc.
- LED status indicates relay ON/OFF state.
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- For easy accessibility input signal pin connected to burg sticks
- Operating temperature: -40 to 85 degrees Celsius
- Dimension: 76*56*17mm
- Weight: 7gm
ADXL345
- Supply voltage: 3.3V/5V
- Communication type: I2C/SPI
- Sensing range: +/-2G to +/-16G
- Sensitivity
- X: 28.6 LSB/G
- Y: 31.2 LSB/G
- Z:34.5 LSB/g
- On-board LDO voltage regulator
- Resolution: 13 bit
- Single tap/double-tap detection
- Embedded memory management system with FIFO
- 10000g shock survival
- Low power consumption as low as 23 µA in measurement mode and 0.1 µA in standby mode at VS = 2.5 V (typical)
- 3-axis MEMS accelerometer
- Ideal for noisy power environment
- Operating temperature: -40 degrees to 85 degrees Celsius
- Dimension: 28*14mm
MQ3 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 0.05 mg/L to 10 mg/L
- Sensitive to Alcohol, Benzine, CH4, Hexane, LPG, CO
- High Sensitivity to Alcohol & small sensitivity to Benzine.
- Digital Out is High or Low based on an adjustable preset threshold,
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes

Reviews
There are no reviews yet.