I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ2 module
₹250.00 Original price was: ₹250.00.₹175.00Current price is: ₹175.00. inc. GST
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 300 -10000 ppm
- Sensitive to H2, LPG, CH4, CO, Alcohol, Smoke or Propane,
- Digital Out is High or Low based on an adjustable preset threshold,
- High Sensitivity to Smoke & combustible gasses like Hydrogen, LPG & Propane.
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
The MQ-2 sensor module is based on the MQ2 sensor that provides a lower conductivity to clean the air as a gas sensing material. MQ2 sensor is ideal for detection or measuring of LPG, Alcohol, Propane, Hydrogen, CO, and even methane. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality monitoring and gas leakage types of equipment. When the sensor is kept in the environment, the conductivity increases with respect to the rise in the concentration of gases. The module comes with basic components integrated allowing the sensor to function properly. And can be interfaced easily to any controller as the user prefers. The MQ2 air monitoring sensor module operates at a voltage of 5V.
MQ2 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON and the digital pin will go from logic high to logic low 0V. LM393 Op-Amp Comparator IC was used to compare the actual gas value with the value set using the potentiometer. The presence of onboard LM393 comparator IC in the MQ2 module also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low.
While using the analogue pin, the analogue values (0-5V) read using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
1 CHANNEL 12V RELAY
- 1-Channel relay interface board
- Operating voltage: 12V DC
- Provide high current relay of 15A
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances
- LED status indicates relay ON/OFF state.
- High current relay of 10A @250 V AC/10A@ 30V DC
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 43*17*17mm
- Weight: 150gm
1 CHANNEL 5V RELAY
- 1 channel relay board
- Operating voltage: 5V
- Maximum current: 2 A
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- configured as SINGLE POLE DOUBLE THROW( SPDT)
- LED status indicates relay ON/OFF state.
- Standard TTL level logic controlled
- One normally closed and one normally opened contact
- Compatible with any 5V microcontroller
- Dimension: 43*17*17mm
- Weight: 150gm
4 CHANNEL 5V RELAY
- 4-Channel relay interface board
- Operating voltage range: 3.3V to5V
- Maximum current: 10A
- Supply current: 20 mA
- High current relay of 10A @250 V AC/10A@ 30V DC
- Control signal: TTL level
- For quick and easy connection high-quality screw terminals provided
- Pull-down circuit to avoid malfunction
- Power supply indicator
- Can control both AC & DC appliances such as DC motors, solenoid valves, lamps, etc.
- LED status indicates relay ON/OFF state.
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- For easy accessibility input signal pin connected to burg sticks
- Operating temperature: -40 to 85 degrees Celsius
- Dimension: 76*56*17mm
- Weight: 7gm
4*4 MATRIX KEYPAD
- The maximum current across each button: 3mA
- Easy communication with any microcontroller
- Ultra-thin design
- Adhesive backing provides easy integration
- High price-performance ratio
- Allows microcontroller to scan 8 output pins to check which 16 button
- Long life
- Maximum operating temperature: 0 degrees to 50 degrees Celsius
- Dimension: 70*77*1mm
- Weight: 7.5gm
DC-DC BOOST MODULE 0.9V-5V/5V 600MA USB MOBILE Power Supply Module
- Ultra-compact PFM chip
- Module properties: nonisolated step-up module
- Input voltage: 1v-5v
- Output voltage: 5.1v-5.2V
- Output current: rated 1A-1.5A
- Efficiency: 96%
- Output ripple: 30mv for 20M bandwidth
- Switching frequency: 500khz
- Voltage indication for led lights with load( for less than 2.7v led indicator off)
- Operating temperature:-40 degrees to 85 degrees Celsius
- Full load temperature rise: 30 degrees Celsius
- Quiescent current: 130ua
- Load regulation: +/-1%
- Voltage regulation: +/-0.5%
- Dynamic response speed: 5% 200Us
- Short circuit protection
- Reverse polarity protection
- Dimension: 2.5*1.8*1.8gm
- Weight: 400gm
DIGITAL POWER AMPLIFIER BOARD MODULE 35W
MQ5 Module
- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.Â
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 33±10%
- Â Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit

Reviews
There are no reviews yet.