I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ3 Sensor
₹225.00 Original price was: ₹225.00.₹200.00Current price is: ₹200.00. inc. GST
- Operating Voltage: 5V ±0.1
- Detecting Concentration: 0.05-10mg/L Alcohol
- Current Consumption : 150mA
- Operation Temperature : -10°C ~ 70°C
- Heater consumption: less than 900mW
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Easy SIP header interface
- Compatible with most of the microcontrollers
- Low-power standby mode
- Requires heater voltage
- Good sensitivity to alcohol gas
- Fast response and High sensitivity
- Requires simple Drive circuit
- Dimensions: 32 x 22 x 16 mm
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ3 sensor also known as Alcohol gas sensor ideal for the detection or measuring of Alcohol, Benzine, CH4, Hexane, LPG, CO. It offers very good sensitivity and a fast response time makes it ideal such as used in gas leakage alarm systems. The MQ3 sensor operates at a voltage of 5V DC and draws around 900mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ3 sensor is a Tin oxide semiconductor sensor designed explicitly to detect Alcohol concentration from 0.05 mg/L to 10 mg/L. It offers very good sensitivity and fast response to alcohol. When the target gas contains the content of alcohol, the sensor’s conductivity is higher alongside the gas concentration rising. As MQ3 gas sensor offers high sensitivity to Alcohol and has good resistance to disturb of gasoline, smoke, and vapour. This sensor provides an analogue resistive output supported alcohol concentration and digital output.
The resistance varies inside the sensor on the detection of alcohol. Therefore more the alcohol content exhibits the lower the resistance. Thus the alcohol content is measured by measuring this resistance. As a result, the sensor and load resistor in the module form a potential divider, and therefore the lower the sensor resistance, the upper the voltage reading is going to be.
Applications:
- Gas level over-limit alarm
- Breathalyzer
- Portable alcohol detector
- Stand-alone/background sensing device
- Environmental monitoring equipment

Related products
DHT11 Sensor
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 33±10%
- Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews
There are no reviews yet.