I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ3 Sensor
₹225.00 Original price was: ₹225.00.₹200.00Current price is: ₹200.00. inc. GST
- Operating Voltage: 5V ±0.1
- Detecting Concentration: 0.05-10mg/L Alcohol
- Current Consumption : 150mA
- Operation Temperature : -10°C ~ 70°C
- Heater consumption: less than 900mW
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Easy SIP header interface
- Compatible with most of the microcontrollers
- Low-power standby mode
- Requires heater voltage
- Good sensitivity to alcohol gas
- Fast response and High sensitivity
- Requires simple Drive circuit
- Dimensions: 32 x 22 x 16 mm
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ3 sensor also known as Alcohol gas sensor ideal for the detection or measuring of Alcohol, Benzine, CH4, Hexane, LPG, CO. It offers very good sensitivity and a fast response time makes it ideal such as used in gas leakage alarm systems. The MQ3 sensor operates at a voltage of 5V DC and draws around 900mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ3 sensor is a Tin oxide semiconductor sensor designed explicitly to detect Alcohol concentration from 0.05 mg/L to 10 mg/L. It offers very good sensitivity and fast response to alcohol. When the target gas contains the content of alcohol, the sensor’s conductivity is higher alongside the gas concentration rising. As MQ3 gas sensor offers high sensitivity to Alcohol and has good resistance to disturb of gasoline, smoke, and vapour. This sensor provides an analogue resistive output supported alcohol concentration and digital output.
The resistance varies inside the sensor on the detection of alcohol. Therefore more the alcohol content exhibits the lower the resistance. Thus the alcohol content is measured by measuring this resistance. As a result, the sensor and load resistor in the module form a potential divider, and therefore the lower the sensor resistance, the upper the voltage reading is going to be.
Applications:
- Gas level over-limit alarm
- Breathalyzer
- Portable alcohol detector
- Stand-alone/background sensing device
- Environmental monitoring equipment

Related products
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
MQ2 module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 300 -10000 ppm
- Sensitive to H2, LPG, CH4, CO, Alcohol, Smoke or Propane,
- Digital Out is High or Low based on an adjustable preset threshold,
- High Sensitivity to Smoke & combustible gasses like Hydrogen, LPG & Propane.
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 33±10%
- Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews
There are no reviews yet.