I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ4 Module
₹250.00 Original price was: ₹250.00.₹175.00Current price is: ₹175.00. inc. GST
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- DOUT: TTL output
- AOUT: Analog output
- Detection Gas: Natural gas/Methane
- Detection range: 300 to 10000ppm
- Digital Out is High or Low based on an adjustable preset threshold,
- Stable & Long Life.
- Onboard Power indication
- Standard Encapsulation Bakelite, Metal cap
- Good sensitivity to Combustible gas in a wide range
- High sensitivity to CH4, Natural gas.
- Small sensitivity to alcohol, smoke.
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
The MQ-4 module is based on the MQ4 Methane gas sensor as a gas sensing element. MQ-4 sensor is ideal for detection or measuring of Natural gas CNG concentration at a range from 300 to 10000ppm. It offers very good sensitivity and fast response to Methane and also shows small sensitivity to alcohol & smoke makes it ideal for use in natural gas monitoring systems. The module comes with basic components integrated allowing the sensor to function properly. And interfaced easily to any controller as the user prefers. Hence no external components are required, we need to just plug in Vcc & ground pins and you are ready to go.
MQ4 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON. As a result, the digital pin will go from logic high to logic low 0V. The presence of onboard LM393 comparator IC in the MQ4 module compares the adjustable preset value and also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low. MQ4 natural gas sensor module can be easily interfaced to any Microcontroller, Arduino, or even Raspberry Pi.
While using the analogue pin to measure PPM, the TTL drove (0-5V) analogue pins read values using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
1 CHANNEL 5V RELAY
- 1 channel relay board
- Operating voltage: 5V
- Maximum current: 2 A
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- configured as SINGLE POLE DOUBLE THROW( SPDT)
- LED status indicates relay ON/OFF state.
- Standard TTL level logic controlled
- One normally closed and one normally opened contact
- Compatible with any 5V microcontroller
- Dimension: 43*17*17mm
- Weight: 150gm
2 CHANNEL 5V RELAY
- High current relay
- Two LED S to indicate relays ON/OFF status
- Low-level trigger expansion board
- Opto isolation circuitry
- Works with logic level signal 3.3V or 5V devices
- Can be used as normally open (NO) or normally closed (NC)
- Back EMF protection
- Ensures diode current protection
- AC control voltage: 250v @mx10A
- DC control voltage: 30V @max 10A
- Easy installation and fixing
4*3 MATRIX KEYPAD
- Operating voltage: 12V DC
- The maximum voltage across each button: 24v
- The maximum current across each button: 3mA
- Ultra-thin design
- Adhesive backing provides easy integration
- Easy communication with any microcontroller
- Flexible
- Only 7 microcontroller pins required to access 12 keys
- High price-performance ratio
- Allows microcontroller to scan 8 output pins to check which 16 button
- Long life
- Maximum operating temperature: 0 degrees to 50 degrees Celsius
- Dimension: 70*77*1mm
- Weight: 7.5gm
4*4 MATRIX KEYPAD
- The maximum current across each button: 3mA
- Easy communication with any microcontroller
- Ultra-thin design
- Adhesive backing provides easy integration
- High price-performance ratio
- Allows microcontroller to scan 8 output pins to check which 16 button
- Long life
- Maximum operating temperature: 0 degrees to 50 degrees Celsius
- Dimension: 70*77*1mm
- Weight: 7.5gm
DS3231 RTC MODULE
- Operating voltage of DS3231: 2.3 v to 5.5v
- 400Khz I2C interface
- Automatic power failure battery switch circuitry
- RTC counts seconds, minutes, hours, and year
- High precision clock chip DS3231
- Programmable square-wave output
- Chip temperature sensor accuracy:+/_3 degree Celsius
- Memory chip: AT24C32 with 32K storage capacity
- CR2032 battery backup with a high life span
- Low power consumption
- Register for ageing trim
- Dimension: 38mm*22mm*14mm
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 31±10%
- Â Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes

Reviews
There are no reviews yet.