- Interface Type: Analog & Digital
- Working voltage: DC 5V
- DOUT: TTL output
- AOUT: Analog output
- Detection Gas: Natural gas/Methane
- Detection range: 300 to 10000ppm
- Digital Out is High or Low based on an adjustable preset threshold,
- Stable & Long Life.
- Onboard Power indication
- Standard Encapsulation Bakelite, Metal cap
- Good sensitivity to Combustible gas in a wide range
- High sensitivity to CH4, Natural gas.
- Small sensitivity to alcohol, smoke.
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
The MQ-4 module is based on the MQ4 Methane gas sensor as a gas sensing element. MQ-4 sensor is ideal for detection or measuring of Natural gas CNG concentration at a range from 300 to 10000ppm. It offers very good sensitivity and fast response to Methane and also shows small sensitivity to alcohol & smoke makes it ideal for use in natural gas monitoring systems. The module comes with basic components integrated allowing the sensor to function properly. And interfaced easily to any controller as the user prefers. Hence no external components are required, we need to just plug in Vcc & ground pins and you are ready to go.
MQ4 module consists of both digital and analogue outputs. This module not only provides a binary indication of the presence of combustible gases but also an analogue representation of their concentration in air. When gas is detected using the digital output, the indicator LED D0 turns ON. As a result, the digital pin will go from logic high to logic low 0V. The presence of onboard LM393 comparator IC in the MQ4 module compares the adjustable preset value and also eliminates the need for an external microcontroller. Simply power up the module and set the sensitivity of the digital pin using the potentiometer. So when the module detects the gas the digital pin will go low. MQ4 natural gas sensor module can be easily interfaced to any Microcontroller, Arduino, or even Raspberry Pi.
While using the analogue pin to measure PPM, the TTL drove (0-5V) analogue pins read values using a microcontroller that calculates the resistance value. By using the external load resistance the resistance variation is converted into a suitable voltage variation. This will be directly proportional to the concentration of the gas to which the sensor detects.

Related products
4 CHANNEL 12V RELAY
- 4-Channel relay interface board
- Relay input voltage: 12V DC
- Relay output: 5A/250V AC
- Signal input:5V DC from the microcontroller
- High current relay of 10A @250 V AC/10A@ 30V DC
- For quick and easy connection high-quality screw terminals provided
- Can control both AC & DC appliances such as DC motors, solenoid valves, lamps, etc.
- LED status indicates relay ON/OFF state.
- Power battery terminal for relay output and aux power connection
- Standard interface that can be controlled by a microcontroller (Arduino, 8051, PIC, AVR, DSP, ARM)
- Relay can directly control all equipment’s and loads
- For easy accessibility input signal pin connected to burg sticks
- Dimension: 165*65*1mm
- Weight: 7gm
CURRENT SENSOR ACS712 30AMPS
- Current sensor chip: ACS712ELC-30A
- Supply voltage: 4.5V to 5.5V DC
- Current range: -30A to 30A
- Sensitivity: 66 millivolt/ampere
- Low noise analogue signal path
- Output rise time: 5 micro sec
- Extremely stable output offset voltage
- Zero magnetic hysteresis
- Factory trimmed for accuracy
- Easy to interface with a microcontroller, since it outputs an analogue voltage
- Onboard power indicator
- Dimension: 7*5*5cm
- Weight: 400gm
DS3231 RTC MODULE
- Operating voltage of DS3231: 2.3 v to 5.5v
- 400Khz I2C interface
- Automatic power failure battery switch circuitry
- RTC counts seconds, minutes, hours, and year
- High precision clock chip DS3231
- Programmable square-wave output
- Chip temperature sensor accuracy:+/_3 degree Celsius
- Memory chip: AT24C32 with 32K storage capacity
- CR2032 battery backup with a high life span
- Low power consumption
- Register for ageing trim
- Dimension: 38mm*22mm*14mm
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 31±10%
- Â Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 33±10%
- Â Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
MQ7 Module
- Operating voltage: DC 5 V.
- Interface Type: Analog
- The analogue output voltage, the higher the concentration the higher the voltage.
- Detection Gas: carbon monoxide
- Detection range: 10 to 10000ppm
- Â Four screw holes for easy positioning.
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm