I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ6 SENSOR
₹175.00 Original price was: ₹175.00.₹150.00Current price is: ₹150.00. inc. GST
- Power requirements: VCC – 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 33±10%
- Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ6 sensor also known as MQ-6 LPG Liquid Propane Gas Sensor ideal for the detection or measuring of LPG, Butane, and Propane. It measures gases at a concentration range from 200 to 10000ppm. It offers excellent sensitivity and fast response to LPG, iso-butane, propane, and LNG and also shows a small sensitivity to alcohol,
cooking fume and cigarette smoke. This makes it ideal for use in LPG gas monitoring and leakage types of equipment. The MQ6 sensor operates at a voltage of 5V DC and draws around 750mW. It provides a lower conductivity to clean air as a gas sensing material. When the target gas contains the content of LPG, the sensor’s conductivity goes higher alongside the gas concentration rising.
MQ6 sensor is a Tin oxide semiconductor sensor designed with higher sensitivity to LPG. This sensor can detect gas either by digital pin or by analogue pin. The digital low signal light is accessed through the IO ports on the Microcontroller. The analogue output is a concentration, i.e. increasing voltage is directly proportional to increasing concentration. The resistance varies inside the sensor on the detection of LPG and butane. Hence by using the external load resistance the resistance variation is converted into a suitable voltage variation. A small potentiometer in this sensor permits the adjustment of the sensitivity of the sensor circuit. Therefore more the Methane content exhibits the lower the resistance. This sensor features long life, low cost, and reliable stability make it particularly suitable for natural gas monitoring applications.
Applications:
- Detector measure Gases like LPG, and butane
- Air quality monitor
- Gas leak alarm
- Safety standard maintenance
- Maintaining environmental standards in hospitals

Related products
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
MQ5 Module
- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ8 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Dual signal output (analogue output, and TTL level output)
- Detection Gas: Hydrogen
- Detection range: 100 to 10, 000 ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller)
- Onboard Power indication
- Good sensitivity to Combustible gas in a wide range
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference.
- Simple drive circuit
- An indication of the signal output
- High sensitivity to hydrogen.
- The higher the voltage, the concentration of the analogue output voltage is higher.
- Four screw holes for easy positioning
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews