SEN-PPI150 PP Vertical Magnetic Water Level Switch Liquid Level Switch Float Level Switch
₹250.00 Original price was: ₹250.00.₹230.00Current price is: ₹230.00. inc. GST
- Model Number: SEN-PPI150.
- Rated voltage: Below DC24V.
- Installation method: vertical.
- 10W, normally open type.
- Float Ball diameter 24mm
- Fixed Screw M10.
- Switch response time: 0.2ms.
- Colour: white colour.
- Material: Plastic PP.
SEN-PPI150 PP vertical magnetic water level switch design based on a mechanically actuated floating switch used to sense the level of liquid in a tank. These float switches designed to activate electrical components, such as pumps, to start and stop automatically by placing vertically in the water. Due to their high reliability, economical pricing, and easy installation these offer a wide range of applications.
A Float sensor defines as a simple water level indicator. This water level controller used in a pump, an indicator, an alarm, or other devices. It is actually a Magnetic float sensor with an electromagnetic ON/OFF switch that floats on top of a liquid surface. The float switch is to open or close a circuit as the liquid level rises or falls. Float switches designed as “normally opened, condition indicates that the two wires from the top of the switch form a complete circuit.
The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Therefore these Float switch materials designed to resist the deleterious effects of corrosive process liquids. Moreover, the liquid with high viscosity cannot be measured. In case if the pressure inside of the tank is high or the liquid’s specific gravity is low, the float will not operate. So these conditions not permitted for liquid level detection. Normally the float sensor failure occurs due to overloading, frequently caused by spiking voltage.
Note:
- This float sensor installed vertically.
- The installation environment to avoid interference of strong magnetic
- The proximity switch shall not be pressed or dropped
- Avoid being stall in shaking liquid, because the power of dry reed pipe in small power
- Operate with intermediate relay, No direct access to high voltage

Related products
250V Float Switch Sensor for Water Level Controller-Big
- Protection: Waterproof
- Medium Working Pressure: Max 1 Bar
- Circuit Breaking Capacity: Directly KW with 250V
- Medium Temperature: 70 Deg.C.
- Mechanical endurance: ≥100,000 times
- Electrical endurance: ≥500,000 times
- Cable length: 3m
- Corrosion Free,
- Sturdy and durable & need no maintenance.
- No current / voltage is passed through water, therefore no electrolysis or Salt deposition.
- Long life (approximate 10 million operations)
- Rust proof (entire sensor body in polypropylene)
- Used in hard water or fuel such as diesel, kerosene, oil etc.
- Dimensions : 11 x 9 x 5cms
- Weight 690 grams
Brass G1/4″ BSP Hall Effect Flow Sensor Water 0.35-3.0L/min OD12 WaterTurbine Flowmeter SEN-HZ41WC
- Water quality requirement: Drinking water health standards, 0-80℃.
- Flow range: 0.35 -0 Liter/min.
- Withstand hydraulic pressure: ≤1.75 MPa.
- Operating voltage: DC 4.5 - 18 Volt
- Operating current: ≤15mA.
- Insulation resistance: >100MΩ.
- Electrical strength: AC500V, 50HZ.
- Output level: Rated voltage DC5V, high level ≥4.5 Volt, low level ≤0.5 Volt.
- Pulse duty cycle: 50%.
- Flow characteristic: F=73Q, F: HZ, Q: L/min,±10%.
- Cumulative flow conversion: 1 Litre water=1780 pulse, accuracy: 8%.
FLOAT SWITCH
Floating Ball Valve Automatic Float Valve Water Level Control Valve F/ Water Tank Water Tower
- Material: plastic
- Form: diaphragm type
- Connection form: thread
- Drive mode: float control
- Flow direction: one direction
- Nominal diameter:15mm
- Automatic control, less water from the fill, the water from the stop.
- Quarter of the inlet, a large amount of water.
- The appearance of fine, small size, practical, simple installation.
Floating Straight Automatic Water Level Control For Water Tank-14014449MG
- Automatic Control, Low Self-Complementary Water, Water Full Automatic Stop.
- Four Intakes, Large Volume Of Water.
- Beautiful Appearance, Small Size, Practical, Simple Installation.
- Without Electricity, Easy To Use, Long Life, Low Failure Rate, Saving Water Resources.
- Working Pressure Range: 0.2-10Kg.
- Applicable Medium: Clean Water.
- Applicable Medium Temperature: ≤70degree C
- Resistance to High-Temperature to Medium Temperature: 70degree to 120degree C
- Material: Nylon Pa66, Stainless Steel Screws, Food Grade Rubber.
- Diameter: Approx. 46Mm / 1.81Inch.
- Dimension: Approx. 83*71mm
Water Lifting Pump
YF-S201 ½” Water Flow Sensor
- Model: YF-S201
- Sensor Type: Hall effect
- Working Voltage: 5 to 18V DC
- Max current draw: 15mA @ 5V.
- Output Type: 5V TTL
- Pulses per Litre: 450
- Working Flow Rate: 1 to 30 Liters/Minute
- Accuracy: ±10%
- Maximum water pressure: 2.0 MPa
- Working Temperature range: -25 to +80℃
- Working Humidity Range: 35%-80% RH
- Output duty cycle: 50% +-10%
- Output rise time: 0.04us
- Output fall time: 0.18us
- Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min)
- Durability: minimum 300,000 cycles
- 1/2″ nominal pipe connections, 0.78″ outer diameter, 1/2″ of thread.
- The simple and compact module.
- Easy to Install.
- High Sealing Performance.
- High-Quality Hall Effect Sensor.
YF-S402 High Precision Flow Meter Water Flow Sensor
- Model: YF-S402
- Minimum rated working voltage: DC 5~24V;
- working current: 15mA (DC 5V);
- Working voltage range: DC 5~18V;
- Load capability: <= 10mA (DC 5V);
- Working temperature: <= 80'C;
- Humidity range: 35%~90%RH (no frost);
- Water pressure: <1.75Mpa;
- Storage temperature: -25~80'C; Storage humidity: 25~95%RH;
- Flow range: 1~5L/min'; Frequency: 4380 pulse for 1L through the sensor
- Dimensions: 2.28 in x 1.38 in x 1.06 in (5.8 cm x 3.5 cm x 2.7 cm)
- Thread Size : G1/4"