I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Water Float Sensor Black
₹225.00 Original price was: ₹225.00.₹175.00Current price is: ₹175.00. inc. GST
- Rating contract (Max.): 10 W
- Switching power supply (Max.): 110VDC
- Resistance contract (Max.): 100 Ω
- Breakdown Voltage (Max.): 220VDC
- Current (Max.): 1A
- Body Total Length (mm) : 85
- Cable Length (cm) : 3
- Total Float opening: 70
- Float Switch ON/OFF angle: Approx. between 15 to 20
- Operating Temperature (C): -10 to 60
- Cable length: 40cm
- No electrical contact with water.
- Shockproof
- Corrosion-free and rust-free
- Float Ball Size: 24×17mm
- Weight : 0.02 kg
Out of stock
A Float sensor defines as a simple water level indicator used to detect the level of liquid within a tank. This water level controller is used in a pump, an indicator, an alarm, or other devices. A water level controller is actually a Magnetic float sensor with an electromagnetic ON/OFF switch that floats on top of a liquid surface.
This sensor works by sensing the level of water present in the overhead tank or sump. These sensors consist of a permanent magnet and the Switch is present in the white stem of the sensor. The magnet in the float activates the switch in the sensor, as soon as the float rises or falls with the level of water in the tank. Thereby the signal output is obtained from the sensors used along with the water level controllers for controlling the motor pump.
The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Thus the Float switch materials are designed to resist the deleterious effects of corrosive process liquids. In most of the systems, a properly selected and sized float detects the interface level between two liquids of different densities. Under the circumstances, the liquid with high viscosity cannot be measured. In case the pressure inside of the tank is high or the liquid’s specific gravity is low, the float will not operate. So these conditions are not permitted for liquid level detection.
APPLICATION
- Hydroponics
- Saltwater Tank,
- Freshwater Tank,
- Gardening, Aquariums for power head control
- Pet Bowls, Fish Tanks, Filtration, Heating, or whatever your project may be.

Related products
Anti-Corrosion Water Level Sensor with Ball Float Switch
- Rating Contract (Max.): 10 W
- Switching Power Supply (Max.): 110VDC
- Pulse current (Max.): 0.5A
- Breakdown Voltage (Max.): 220VDC
- Current (Max.): 1A
- Resistance Contract (Max.): 100 Ω
- Operating Temperature: -10 to 60degree C
- Cable length: 40cm
- Shipment Weight: 0.02 kg
- Float Ball Size : 24×17mm
- Body Total Length: 85mm
- Total Float opening: 70°
- Float Switch ON/OFF angle: Approx. between 15° to 20°
DS18B20 MODULE
- Resolution: 9bits to 12bits (Selectable)
- Supply Voltage (V): 3 to 5.5
- Temperature Range(°C): -55 to +125
- Measuring Accuracy(°C): ±0.5
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into the chip
- Multiple sensors can share one pin
- Maximum conversion time and response: 750 ms
- Multidrop capability simplifies distributed temperature sensing applications
- Requires no external components
- Digital signal output
- 18B20 Temperature Sensor Chip
- Send data via a pin
- User-definable nonvolatile (NV) alarm settings
- Dimension: 19*15*6cm
- Weight: 9gm
DS18B20 PROBE
- Usable temperature range: -55 to 125°C (-67°F to +257°F)
- 9 to 12-bit selectable resolution
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into a chip
- Multiple sensors can share one pin
- ±0.5°C Accuracy from -10°C to +85°C
- Temperature-limit alarm system
- Query time is less than 750ms
- Usable with 3.0V to 5.5V power/data
- Each pin uses a heat-shrinkable tube to prevent short circuit, internal sealing glue.
- Stainless steel tube encapsulation waterproof moistureproof prevents rust.
- Stainless steel tube 6mm diameter by 30mm long.
- Contains DS18B20 temperature sensor.
- Uses 1-Wire interface- requires only one digital pin for communication.
- Unique 64 bit ID burned into the chip.
- Multiple sensors can share one pin.
- Temperature-limit alarm system.
- Without the external components, the unique single bus.
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm

Reviews