- Capacity: 10Kg
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals(N max): 2000
- Minimum number of load cell verification intervals(Vmin): E Max/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(O): 402±6
- Output resistance(O): 350±3
- Insulation resistance(MO<50V>): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2*350mm
- Dimensions : 15.9 x 14.1 x 2.7 cm
- weight: 190gm
A load cell transducer/sensor creates an electrical signal whose magnitude is directly proportional to the force measured. The various types of load cells include hydraulic load cells, pneumatic load cells, and strain gauge load cells. The standard straight bar load cell 10kg (sometimes called a strain gauge) translates up to 10 kg of pressure (force) into an electrical signal. Each load cell 10kg measures the electrical resistance that changes is proportional to the strain (e.g. pressure or force) applied to the bar. The output of the load cell is in milli-volts and cannot be directly measured by a micro-controller. So an ADC with high resolution or an instrumentation amplifier reads the output of the load cell to the microcontroller.
The intensity of deformity defines how much force applied, and this value digitally sent to an interface module. This gauge can determine how heavy an object is, whether the object’s weight changes over time or if you simply need to sense the object by measuring strain or load applied to a surface. This straight bar load cell made from an aluminum alloy. And it is capable of reading a capacity of 10KG of weight. These load cells also provide an IP66 protection rating for the sensor.
The load cell has four lead wires which connect HX711 A/D Pressure Sensor. It is easy to use with a driving voltage of 5-10V and produces the output voltage as the force changes.
Due to its high accuracy, it has a wide range of applications in the electronic platform scale, Digital scale, etc

Related products
125 KHz RFID CARD THICK
4 WIRE RESISTIVE TOUCH SCREEN MUX BREAK OUT BOARD
530pcs Colorful Heat Shrink Tubing Insulation Set
- Material: Polyolefin
- Shrinkage Ratio: 2:1 (will maximum shrink to 1/2 its supplied diameter)
- Minimum Shrinkage Temp: ≥84°C
- Full Shrinkage Temp: ≥120°C
- Operating Temperature: -55°C to +125°C
- Tensile strength: 10.4 Mpa
- Dielectric strength: 15 KV/mm
- Manufacture specification: ISO9001
- Cutting method: scissors or sharp Flammability knife: hardly flammable Package size: approx. 190*130*36mm
- Package include : 530pcs x Heat Shrink Tubing Insulation Shrinkable Tube
5pcs x NFC Sticker tags 13.56MHz ISO14443A 25mm Ntag213 RFID NFC tag
- Chip: Ntag213.
- Physical capacity: 180 bytes.
- Usable capacity: 144 bytes.
- Protocol: ISO14443A.
- Working frequency: 13.56 MHZ.
- Reading and writing distance: 1 to 5 cm.
- Reading and writing time: 1 to 2 ms.
- Working temperature: -20 to 55 degrees, the humidity of 90%.
- Erase times : > 100000 times.
- Data storage: > 10 years.
- Reading time: 100000 times.
- Diameter: 25mm.
- Materials: PE self-adhesive + coated paper.
- Manufacturer programmed 7-byte UID for each device
- Preprogrammed Capability container with one-time programmable bits
- Field programmable read-only locking function
- ECC-based originality signature
- 32-bit password protection to prevent unauthorized memory operations
- NFC Forum Tag 2 Type compliance
5V-12V ZVS Induction Low Voltage Heating Power Supply Module Board + Coil
LOAD CELL 5Kg
- Capacity: 5Kg
- Rated output(MV/V): 2.0±0.15
- Accuracy class: C2
- Maximum number of load cell verification intervals(N max): 2000
- Minimum number of load cell verification intervals(Vmin): E Max/5000
- Combined error(%RO): <±0.030
- Creep(%RO/30min): 0.03
- Temperature effect on sensitivity(%RO/°C): 0.0016
- Temperature effect on zero(%RO/°C): 0.003
- Zero balance(%RO): 1.0
- Input resistance(O): 402±6
- Output resistance(O): 350±3
- Insulation resistance(MO<50V>): 5000
- Recommended excitation voltage(V): 10~15
- Compensated temperature range(°C): -10~+40
- Operating temperature range(°C): -35~+80
- Safe overload(%RO): 150
- Ultimate overload(%RO): 200
- Load cell material: Aluminium
- Connecting cable: ø4.2*350mm
- Dimensions :3.45 x 2.4 x 0.9 inches
- weight:25gm
SP1848-27145 40x40mm Thermoelectric Power Generator TEG 150°C Peltier Module
- Model: SP1848-27145
- Open Circuit Voltage: 4.8 V
- Operating Temperature: 0 to 150 C
- Maximum Temperature: 150 Degree C
- Wire Length: 350mm
- 350Small and lightweight, convenient for use.
- Designed specifically for power generation.
- Sealed for moisture protection and contain thermal elements formulated for optimum Seebeck power generation.
- High-temperature 150C, with NM static protection.
- Quality tested cooling cells.
- Simple to install and operate.
- With 5v Booster board you can charge the cell phone
UNI T Infrared Thermometer UT30R
- Measurement range: 32 to 45 ° C.
- Resolution: 0.1 ° C.
- Test distance: 5-10 cm
- Accuracy : ± 0.3°C
- Measurement repeatability : 0.3°C
- Response time : 500 ms
- Optical measuring range : 5.5μm ~ 14.0μm
- Simple, fast and accurate IR thermometer
- Flashing arm at high temperature (more than 37.2 ° C)
- Single button operation
- LCD display with backlight for dark condition
- Auto data hold for 8s
- Â Auto power off
- Low voltage indication
- Option of Celsius/Fahrenheit
- Power-off memory function