- Material: Aluminium alloy
- Rated load: 40KG
- Comprehensive error: 0,03% F.S.
- Rated output: 2±0.02mV/V
- Repeatability : 0.01% Full scale
- Zero Balance : +/- 1% Full scale
- Excitation Voltage: 9~12V
- Safe Load: 120% of Rated Capacity
- Ultimate Load: 150% of Rated Capacity
A load cell transducer/sensor generates an electrical signal whose magnitude is directly proportional to the force measured. The standard straight bar load cell 40kg (sometimes called a strain gauge) translates up to 40 kg of pressure (force) into an electrical signal. Each load cell 40kg measures the electrical resistance that changes is proportional to the strain (e.g. pressure or force) applied to the bar. The output of the load cell is in milli-volts and cannot be directly measured by a micro-controller. So an ADC with high resolution or an instrumentation amplifier reads the output of the load cell to the microcontroller.
The intensity of deformity defines how much force is applied, and this value is digitally sent to an interface module. This gauge can determine how heavy an object is, whether the object’s weight changes over time or if you simply need to sense the object by measuring strain or load applied to a surface. This straight bar load cell is made from an aluminium alloy. And it is capable of reading a capacity of 40KG of weight. These load cells also provide an IP65 protection rating for the sensor.
Here each load cell consists of four strain gauges connected into a Wheatstone bridge. Wheatstone bridge is basically two potential dividers connected in parallel. Here SG1 and SG2 form one of the potential divider circuits. Similarly, SG3 and SG4 form the other divider circuit. Output voltage for the load cell taken from the midpoint of the potential divider circuits. Therefore, when strain is applied to the bridge, the gauge measures the strain as an electrical signal, because the strain changes the electrical resistance of the wire.

Related products
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
GP2Y0A21YK0F 10-80cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 10 cm to 80 cm
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: : 29.5×13×13.5 mm
- Weight: 3.5 gm
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant