I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Load Cell CZL 601 40KG
₹500.00 Original price was: ₹500.00.₹450.00Current price is: ₹450.00. inc. GST
- Material: Aluminium alloy
- Rated load: 40KG
- Comprehensive error: 0,03% F.S.
- Rated output: 2±0.02mV/V
- Repeatability : 0.01% Full scale
- Zero Balance : +/- 1% Full scale
- Excitation Voltage: 9~12V
- Safe Load: 120% of Rated Capacity
- Ultimate Load: 150% of Rated Capacity
A load cell transducer/sensor generates an electrical signal whose magnitude is directly proportional to the force measured. The standard straight bar load cell 40kg (sometimes called a strain gauge) translates up to 40 kg of pressure (force) into an electrical signal. Each load cell 40kg measures the electrical resistance that changes is proportional to the strain (e.g. pressure or force) applied to the bar. The output of the load cell is in milli-volts and cannot be directly measured by a micro-controller. So an ADC with high resolution or an instrumentation amplifier reads the output of the load cell to the microcontroller.
The intensity of deformity defines how much force is applied, and this value is digitally sent to an interface module. This gauge can determine how heavy an object is, whether the object’s weight changes over time or if you simply need to sense the object by measuring strain or load applied to a surface. This straight bar load cell is made from an aluminium alloy. And it is capable of reading a capacity of 40KG of weight. These load cells also provide an IP65 protection rating for the sensor.
Here each load cell consists of four strain gauges connected into a Wheatstone bridge. Wheatstone bridge is basically two potential dividers connected in parallel. Here SG1 and SG2 form one of the potential divider circuits. Similarly, SG3 and SG4 form the other divider circuit. Output voltage for the load cell taken from the midpoint of the potential divider circuits. Therefore, when strain is applied to the bridge, the gauge measures the strain as an electrical signal, because the strain changes the electrical resistance of the wire.

Related products
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
Force Sensor 5.08mm
- Two pins extend from the bottom of the sensor with 0.1″ pitch making it bread friendly.
- Device Rise Time: <3 microseconds
- Easily customizable to a wide range of sizes
- Actuation Force: 0.1 Newtons
- Cost-effective
- Ultra-thin; 0.45 mm
- Robust; up to 10 million actuation
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Simple and easy to Integrate.
- Non-Actuated Resistance: 10M W
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
GP2Y0A710K0F 100-550cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 100 cm to 550 cm
- LM2596 Based design
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: 58*17.6*22.5mm
- Weight: 3.5 gm
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- - Ambient temperature : -20 ~ +55
- - Humidity: 95% RH
- - Environmental oxygen content: 21%
- Storage conditions :
- - Temperature : -20 ~ +70
- - Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm

Reviews
There are no reviews yet.