I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Metal Detector Sensor
- Low battery indicator
- Multiple Modes
- VCC 9V Battery
- Logic high output with common ground
- Can detect any metal at the range of 1Cm to 3Cm, you can connect a 9V battery to make it handy
- It will not detect coins if it is in the middle of the coil, it may detect if it is close to the coil, It will not detect any type of explosives
- The metal sensor has to supply 12V from controllers and not 12V via adapter
A metal detector is defined as an electronic instrument used to detect the presence of metal nearby. Metal detectors are widely used for finding metal inclusions hidden within objects, or metal objects buried underground. This metal detector module basically consists of a handheld unit with a sensor probe that swept over the ground or other objects. If a piece of metal comes in the sensor range, indicated by a changing tone in earphones, or a needle moving on an indicator. When a target is detected the metal detector generates an audible response, such as a beep or change in tone. Basically, the device gives some indication of distance; which means the closer the metal is, the higher the tone in the earphone or the higher the needle goes.
Metal detectors work by transmitting an electromagnetic field from the search coil into the ground. As a result, any metal objects (targets) within the electromagnetic field become energized and retransmit an electromagnetic field of their own. The retransmitted field is received by the detector’s search coil alerts the user by producing a target response. Certain metal detectors can be set to ignore unwanted targets and discriminate between different target types. . The control box in the device contains the detector’s electronics. This is where the transmit signal is generated and the received signal is processed and converted into a target response.
There exist certain cases when unwanted targets are attracted to a detector, normally ferrous (attracted to a magnet), such as nails, but also be non-ferrous, such as bottle tops. If the metal detector is set to reject unwanted targets then a target response is not produced for those targets. The detecting range of the metal detector is “as deep as the diameter of the coil”. So detectors with larger coils will detect deeper. However, detection depth also depends upon detector methods and other environmental factors.

Related products
DS18B20 MODULE
- Resolution: 9bits to 12bits (Selectable)
- Supply Voltage (V): 3 to 5.5
- Temperature Range(°C): -55 to +125
- Measuring Accuracy(°C): ±0.5
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into the chip
- Multiple sensors can share one pin
- Maximum conversion time and response: 750 ms
- Multidrop capability simplifies distributed temperature sensing applications
- Requires no external components
- Digital signal output
- 18B20 Temperature Sensor Chip
- Send data via a pin
- User-definable nonvolatile (NV) alarm settings
- Dimension: 19*15*6cm
- Weight: 9gm
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
Force Sensor 5.08mm
- Two pins extend from the bottom of the sensor with 0.1″ pitch making it bread friendly.
- Device Rise Time: <3 microseconds
- Easily customizable to a wide range of sizes
- Actuation Force: 0.1 Newtons
- Cost-effective
- Ultra-thin; 0.45 mm
- Robust; up to 10 million actuation
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Simple and easy to Integrate.
- Non-Actuated Resistance: 10M W
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
MQ3 Sensor
- Operating Voltage: 5V ±0.1
- Detecting Concentration: 0.05-10mg/L Alcohol
- Current Consumption : 150mA
- Operation Temperature : -10°C ~ 70°C
- Heater consumption: less than 900mW
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Easy SIP header interface
- Compatible with most of the microcontrollers
- Low-power standby mode
- Requires heater voltage
- Good sensitivity to alcohol gas
- Fast response and High sensitivity
- Requires simple Drive circuit
- Dimensions: 32 x 22 x 16 mm
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range

Reviews