I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Metal Detector Sensor
- Low battery indicator
- Multiple Modes
- VCC 9V Battery
- Logic high output with common ground
- Can detect any metal at the range of 1Cm to 3Cm, you can connect a 9V battery to make it handy
- It will not detect coins if it is in the middle of the coil, it may detect if it is close to the coil, It will not detect any type of explosives
- The metal sensor has to supply 12V from controllers and not 12V via adapter
A metal detector is defined as an electronic instrument used to detect the presence of metal nearby. Metal detectors are widely used for finding metal inclusions hidden within objects, or metal objects buried underground. This metal detector module basically consists of a handheld unit with a sensor probe that swept over the ground or other objects. If a piece of metal comes in the sensor range, indicated by a changing tone in earphones, or a needle moving on an indicator. When a target is detected the metal detector generates an audible response, such as a beep or change in tone. Basically, the device gives some indication of distance; which means the closer the metal is, the higher the tone in the earphone or the higher the needle goes.
Metal detectors work by transmitting an electromagnetic field from the search coil into the ground. As a result, any metal objects (targets) within the electromagnetic field become energized and retransmit an electromagnetic field of their own. The retransmitted field is received by the detector’s search coil alerts the user by producing a target response. Certain metal detectors can be set to ignore unwanted targets and discriminate between different target types. . The control box in the device contains the detector’s electronics. This is where the transmit signal is generated and the received signal is processed and converted into a target response.
There exist certain cases when unwanted targets are attracted to a detector, normally ferrous (attracted to a magnet), such as nails, but also be non-ferrous, such as bottle tops. If the metal detector is set to reject unwanted targets then a target response is not produced for those targets. The detecting range of the metal detector is “as deep as the diameter of the coil”. So detectors with larger coils will detect deeper. However, detection depth also depends upon detector methods and other environmental factors.

Related products
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Â Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
GP2Y0A710K0F 100-550cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 100 cm to 550 cm
- LM2596 Based design
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: 58*17.6*22.5mm
- Weight: 3.5 gm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews