I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ8 GAS SENSOR
₹225.00 Original price was: ₹225.00.₹175.00Current price is: ₹175.00. inc. GST
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. A gas sensor is a simple drive circuit that interacts with gas to measure concentration. MQ8 sensor is ideal for the detection of Hydrogen concentration in the air such as portable gas detectors or in other industrial applications. Hydrogen is a colourless, odourless, tasteless, highly flammable nonmetallic gas. MQ8 sensor is a Tin oxide semiconductor sensor designed explicitly for Hydrogen (H2) concentration detection. It offers very good sensitivity and a fast response time, and also has anti-interference to other gases. MQ8 Gas sensor measures hydrogen concentrations ranging from 100 to 10, 000 ppm providing lower conductivity in clean air.
MQ8 works by detecting the hydrogen concentration of cycle high and low temperature and detecting H2 at low temperatures (heated by 1.5V). Analogue resistive output is provided by the sensor with conductivity higher along with the gas concentration rising. The resistance varies inside the sensor on the detection of hydrogen. Under the high temperature (heated by 5.0V), the other gases adsorbed under the low temperature are cleared. We just need to power the heater coil with 5V, add a load resistance. As a result, the sensor and load resistor in the module form a potential divider and connect the output to an ADC or a simple OPAMP comparator.
Thus the hydrogen content is measured by measuring this resistance. Therefore the lower the sensor resistance, the upper the voltage reading is going to be. MQ8 sensor designed to operate at temperatures ranging from -10 to 50°C and consumes less than 150 mA current at 5 V.
Applications of MQ8 Gas Sensor:-
- Domestic gas leakage alarm
- Industrial flammable gas alarm
- Portable gas detector.

Related products
DS18B20 PROBE
- Usable temperature range: -55 to 125°C (-67°F to +257°F)
- 9 to 12-bit selectable resolution
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into a chip
- Multiple sensors can share one pin
- ±0.5°C Accuracy from -10°C to +85°C
- Temperature-limit alarm system
- Query time is less than 750ms
- Usable with 3.0V to 5.5V power/data
- Each pin uses a heat-shrinkable tube to prevent short circuit, internal sealing glue.
- Stainless steel tube encapsulation waterproof moistureproof prevents rust.
- Stainless steel tube 6mm diameter by 30mm long.
- Contains DS18B20 temperature sensor.
- Uses 1-Wire interface- requires only one digital pin for communication.
- Unique 64 bit ID burned into the chip.
- Multiple sensors can share one pin.
- Temperature-limit alarm system.
- Without the external components, the unique single bus.
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
LJ12A3-4-Z/BY PNP DC6-36V 8 mm INDUCTIVE PROXIMITY SENSOR
- Output type: PNP NO
- Supply voltage: 6V-36V
- Current output: 300mA
- Response frequency: 0.5khz
- Detecting distance: 4mm
- Wire type: cylindrical DC 3 wire type
- Switch appearance type: cylinder type
- Operating temperature: -25 degrees to 55 degrees Celsius
- Detect object: iron
- Red led checks proximity status
- High repeated positioning accuracy
- High switching frequency
- Reverse power protection, short circuit protection, directly connecting with PLC
- anti-vibration, dust, water, and oil prevention
- Dimension: 5*3*3cm
- Weight: 400gm
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 33±10%
- Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
MQ7 Module
- Operating voltage: DC 5 V.
- Interface Type: Analog
- The analogue output voltage, the higher the concentration the higher the voltage.
- Detection Gas: carbon monoxide
- Detection range: 10 to 10000ppm
- Four screw holes for easy positioning.
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm

Reviews