I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ3 Sensor
₹225.00 Original price was: ₹225.00.₹200.00Current price is: ₹200.00. inc. GST
- Operating Voltage: 5V ±0.1
- Detecting Concentration: 0.05-10mg/L Alcohol
- Current Consumption : 150mA
- Operation Temperature : -10°C ~ 70°C
- Heater consumption: less than 900mW
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Easy SIP header interface
- Compatible with most of the microcontrollers
- Low-power standby mode
- Requires heater voltage
- Good sensitivity to alcohol gas
- Fast response and High sensitivity
- Requires simple Drive circuit
- Dimensions: 32 x 22 x 16 mm
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ3 sensor also known as Alcohol gas sensor ideal for the detection or measuring of Alcohol, Benzine, CH4, Hexane, LPG, CO. It offers very good sensitivity and a fast response time makes it ideal such as used in gas leakage alarm systems. The MQ3 sensor operates at a voltage of 5V DC and draws around 900mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ3 sensor is a Tin oxide semiconductor sensor designed explicitly to detect Alcohol concentration from 0.05 mg/L to 10 mg/L.  It offers very good sensitivity and fast response to alcohol. When the target gas contains the content of alcohol, the sensor’s conductivity is higher alongside the gas concentration rising. As MQ3 gas sensor offers high sensitivity to Alcohol and has good resistance to disturb of gasoline, smoke, and vapour. This sensor provides an analogue resistive output supported alcohol concentration and digital output.
The resistance varies inside the sensor on the detection of alcohol. Therefore more the alcohol content exhibits the lower the resistance. Thus the alcohol content is measured by measuring this resistance. As a result, the sensor and load resistor in the module form a potential divider, and therefore the lower the sensor resistance, the upper the voltage reading is going to be.
Applications:
- Gas level over-limit alarm
- Breathalyzer
- Portable alcohol detector
- Stand-alone/background sensing device
- Environmental monitoring equipment

Related products
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
GP2Y0A21YK0F 10-80cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 10 cm to 80 cm
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: : 29.5×13×13.5 mm
- Weight: 3.5 gm
LDR SENSOR 20mm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Â The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ2 module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 300 -10000 ppm
- Sensitive to H2, LPG, CH4, CO, Alcohol, Smoke or Propane,
- Digital Out is High or Low based on an adjustable preset threshold,
- High Sensitivity to Smoke & combustible gasses like Hydrogen, LPG & Propane.
- Stable & Long Life.
- Onboard Power indication
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Fast response and recovery
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm

Reviews
There are no reviews yet.