I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ8 GAS SENSOR
₹225.00 Original price was: ₹225.00.₹175.00Current price is: ₹175.00. inc. GST
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. A gas sensor is a simple drive circuit that interacts with gas to measure concentration. MQ8 sensor is ideal for the detection of Hydrogen concentration in the air such as portable gas detectors or in other industrial applications. Hydrogen is a colourless, odourless, tasteless, highly flammable nonmetallic gas. MQ8 sensor is a Tin oxide semiconductor sensor designed explicitly for Hydrogen (H2) concentration detection. It offers very good sensitivity and a fast response time, and also has anti-interference to other gases. MQ8 Gas sensor measures hydrogen concentrations ranging from 100 to 10, 000 ppm providing lower conductivity in clean air.
MQ8 works by detecting the hydrogen concentration of cycle high and low temperature and detecting H2 at low temperatures (heated by 1.5V). Analogue resistive output is provided by the sensor with conductivity higher along with the gas concentration rising. The resistance varies inside the sensor on the detection of hydrogen. Under the high temperature (heated by 5.0V), the other gases adsorbed under the low temperature are cleared. We just need to power the heater coil with 5V, add a load resistance. As a result, the sensor and load resistor in the module form a potential divider and connect the output to an ADC or a simple OPAMP comparator.
Thus the hydrogen content is measured by measuring this resistance. Therefore the lower the sensor resistance, the upper the voltage reading is going to be. MQ8 sensor designed to operate at temperatures ranging from -10 to 50°C and consumes less than 150 mA current at 5 V.
Applications of MQ8 Gas Sensor:-
- Domestic gas leakage alarm
- Industrial flammable gas alarm
- Portable gas detector.

Related products
DS18B20 MODULE
- Resolution: 9bits to 12bits (Selectable)
- Supply Voltage (V): 3 to 5.5
- Temperature Range(°C): -55 to +125
- Measuring Accuracy(°C): ±0.5
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into the chip
- Multiple sensors can share one pin
- Maximum conversion time and response: 750 ms
- Multidrop capability simplifies distributed temperature sensing applications
- Requires no external components
- Digital signal output
- 18B20 Temperature Sensor Chip
- Send data via a pin
- User-definable nonvolatile (NV) alarm settings
- Dimension: 19*15*6cm
- Weight: 9gm
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
LDR SENSOR 20mm
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ6 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Dual signal output (analogue output, and TTL level output)
- Detection Gas: Propane, Butane, and LPG
- Detection range: 300 to 10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller)
- Onboard Power indication
- Good sensitivity to Combustible gas in a wide range
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference.
- Simple drive circuit
- An indication of the signal output
- High sensitivity to hydrogen.
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
MQ8 Module
- Interface Type: Analog & Digital
- Working voltage: DC 5V
- Dual signal output (analogue output, and TTL level output)
- Detection Gas: Hydrogen
- Detection range: 100 to 10, 000 ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller)
- Onboard Power indication
- Good sensitivity to Combustible gas in a wide range
- Can be resistant to ethanol steam, LPG (petroleum), smoke interference.
- Simple drive circuit
- An indication of the signal output
- High sensitivity to hydrogen.
- The higher the voltage, the concentration of the analogue output voltage is higher.
- Four screw holes for easy positioning
- Has a long life and reliable stability.
- Fast response and recovery characteristics.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm

Reviews