I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
MQ8 GAS SENSOR
₹225.00 Original price was: ₹225.00.₹175.00Current price is: ₹175.00. inc. GST
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. A gas sensor is a simple drive circuit that interacts with gas to measure concentration. MQ8 sensor is ideal for the detection of Hydrogen concentration in the air such as portable gas detectors or in other industrial applications. Hydrogen is a colourless, odourless, tasteless, highly flammable nonmetallic gas. MQ8 sensor is a Tin oxide semiconductor sensor designed explicitly for Hydrogen (H2) concentration detection. It offers very good sensitivity and a fast response time, and also has anti-interference to other gases. MQ8 Gas sensor measures hydrogen concentrations ranging from 100 to 10, 000 ppm providing lower conductivity in clean air.
MQ8 works by detecting the hydrogen concentration of cycle high and low temperature and detecting H2 at low temperatures (heated by 1.5V). Analogue resistive output is provided by the sensor with conductivity higher along with the gas concentration rising. The resistance varies inside the sensor on the detection of hydrogen. Under the high temperature (heated by 5.0V), the other gases adsorbed under the low temperature are cleared. We just need to power the heater coil with 5V, add a load resistance. As a result, the sensor and load resistor in the module form a potential divider and connect the output to an ADC or a simple OPAMP comparator.
Thus the hydrogen content is measured by measuring this resistance. Therefore the lower the sensor resistance, the upper the voltage reading is going to be. MQ8 sensor designed to operate at temperatures ranging from -10 to 50°C and consumes less than 150 mA current at 5 V.
Applications of MQ8 Gas Sensor:-
- Domestic gas leakage alarm
- Industrial flammable gas alarm
- Portable gas detector.

Related products
DS18B20 PROBE
- Usable temperature range: -55 to 125°C (-67°F to +257°F)
- 9 to 12-bit selectable resolution
- Uses 1-Wire interface- requires only one digital pin for communication
- Unique 64 bit ID burned into a chip
- Multiple sensors can share one pin
- ±0.5°C Accuracy from -10°C to +85°C
- Temperature-limit alarm system
- Query time is less than 750ms
- Usable with 3.0V to 5.5V power/data
- Each pin uses a heat-shrinkable tube to prevent short circuit, internal sealing glue.
- Stainless steel tube encapsulation waterproof moistureproof prevents rust.
- Stainless steel tube 6mm diameter by 30mm long.
- Contains DS18B20 temperature sensor.
- Uses 1-Wire interface- requires only one digital pin for communication.
- Unique 64 bit ID burned into the chip.
- Multiple sensors can share one pin.
- Temperature-limit alarm system.
- Without the external components, the unique single bus.
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
LJ12A3-4-Z/BY PNP DC6-36V 8 mm INDUCTIVE PROXIMITY SENSOR
- Output type: PNP NO
- Supply voltage: 6V-36V
- Current output: 300mA
- Response frequency: 0.5khz
- Detecting distance: 4mm
- Wire type: cylindrical DC 3 wire type
- Switch appearance type: cylinder type
- Operating temperature: -25 degrees to 55 degrees Celsius
- Detect object: iron
- Red led checks proximity status
- High repeated positioning accuracy
- High switching frequency
- Reverse power protection, short circuit protection, directly connecting with PLC
- anti-vibration, dust, water, and oil prevention
- Dimension: 5*3*3cm
- Weight: 400gm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- - Ambient temperature : -20 ~ +55
- - Humidity: 95% RH
- - Environmental oxygen content: 21%
- Storage conditions :
- - Temperature : -20 ~ +70
- - Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ5 Module
- Operating voltage: 5V
- Interface Type: Analog & Digital
- Dual signal output (analogue output, and TTL level output)
- Detecting concentration:200-10000ppm
- The TTL output signal is low. (When low output signal light, and can be connected directly to the microcontroller
- High Sensitivity to LPG, Natural Gas, Town Gas
- small sensitivity to smoke & alcohol
- Low Cost.
- Stable & Long Life.
- Simple drive circuit.
- Fast response.
- Onboard Power indication.
- Adjustable sensitivity
- Dimension: 32mm x 22m x 27mm

Reviews
There are no reviews yet.