I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
SEN-PPI150 PP Vertical Magnetic Water Level Switch Liquid Level Switch Float Level Switch
₹250.00 Original price was: ₹250.00.₹230.00Current price is: ₹230.00. inc. GST
- Model Number: SEN-PPI150.
- Rated voltage: Below DC24V.
- Installation method: vertical.
- 10W, normally open type.
- Float Ball diameter 24mm
- Fixed Screw M10.
- Switch response time: 0.2ms.
- Colour: white colour.
- Material: Plastic PP.
Out of stock
SEN-PPI150 PP vertical magnetic water level switch design based on a mechanically actuated floating switch used to sense the level of liquid in a tank. These float switches designed to activate electrical components, such as pumps, to start and stop automatically by placing vertically in the water. Due to their high reliability, economical pricing, and easy installation these offer a wide range of applications.
A Float sensor defines as a simple water level indicator. This water level controller used in a pump, an indicator, an alarm, or other devices. It is actually a Magnetic float sensor with an electromagnetic ON/OFF switch that floats on top of a liquid surface. The float switch is to open or close a circuit as the liquid level rises or falls. Float switches designed as “normally opened, condition indicates that the two wires from the top of the switch form a complete circuit.
The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Therefore these Float switch materials designed to resist the deleterious effects of corrosive process liquids. Moreover, the liquid with high viscosity cannot be measured. In case if the pressure inside of the tank is high or the liquid’s specific gravity is low, the float will not operate. So these conditions not permitted for liquid level detection. Normally the float sensor failure occurs due to overloading, frequently caused by spiking voltage.
Note:
- This float sensor installed vertically.
- The installation environment to avoid interference of strong magnetic
- The proximity switch shall not be pressed or dropped
- Avoid being stall in shaking liquid, because the power of dry reed pipe in small power
- Operate with intermediate relay, No direct access to high voltage

Related products
Brass G1/4″ BSP Hall Effect Flow Sensor Water 0.35-3.0L/min OD12 WaterTurbine Flowmeter SEN-HZ41WC
- Water quality requirement: Drinking water health standards, 0-80℃.
- Flow range: 0.35 -0 Liter/min.
- Withstand hydraulic pressure: ≤1.75 MPa.
- Operating voltage: DC 4.5 - 18 Volt
- Operating current: ≤15mA.
- Insulation resistance: >100MΩ.
- Electrical strength: AC500V, 50HZ.
- Output level: Rated voltage DC5V, high level ≥4.5 Volt, low level ≤0.5 Volt.
- Pulse duty cycle: 50%.
- Flow characteristic: F=73Q, F: HZ, Q: L/min,±10%.
- Cumulative flow conversion: 1 Litre water=1780 pulse, accuracy: 8%.
G3/4 Thread Water Flow Sensor Switch Control Meter Flowmeter 1-30L/min SEN-HZ43WB
- Water quality requirement: Drinking water health standards, 0-80℃
- Flow range: 2-45 Liter/min
- Withstand hydraulic pressure: ≤1.75 MPa
- Voltage/electric current: DC 4.5 - 18 Volt , ≤15mA
- Insulation resistance: >100MΩ
- Electrical strength: AC500V, 50HZ
- Output level: Rated voltage DC 5 Volt, high level ≥4.5 Volt, low level ≤0.5 Volt
- Pulse duty cycle: 50%
- Flow characteristic: F=8.1Q-3, F: HZ, Q: L/min,±10%
- Cumulative flow conversion: 1 Liter water=477 pulse, accuracy: 10%
SEN-PPI35 PP Aquarium Liquid Water Level Sensor Float Switches Normally Open
Side Mounted Small Float Level Control Switch
- Rhodium reed switch
- Special handling reed switches in high temperature
- Overall performance and reliable float switch
- Long-lasting life: Up to 100 million times
- Switch Length: 55 mm
- Cable Length: 300 mm
- Special handling reed switches can make it in 140 ˚C high temperature under normal use
- Overall performance and reliable float switch
Water Float Sensor P43
Water flow sensor SEN-HZG1WA Pulse Output 4~45L/min Liquid Switch Flowmeter
- Model: SEN-HZG1WA.
- Use voltage: DC 5V.
- Connect way: G1”, 60*34*34(mm).
- Working voltage range: DC 4.5 ~18V.
- Working current: 15mA.
- Test range: 4~45L/min (m³/h).
- Fit media: water.
- Working pressure: 1.75MPa.
- Outside nominal diameter: G1 (mm).
- Instantaneous flow pulse characteristics: F= [5Q-3]±10%, F means instantaneous pulse value(Hz),Q means instant flow(L/min).
- Insulation resistance = 100MO.
- Electric strength: AC 500V, 50Hz.
- Precision grade: +-10%.
- Working temperature: 60 degree C
- Type: vane-wheel type flowmeter.
YF-S402 High Precision Flow Meter Water Flow Sensor
- Model: YF-S402
- Minimum rated working voltage: DC 5~24V;
- working current: 15mA (DC 5V);
- Working voltage range: DC 5~18V;
- Load capability: <= 10mA (DC 5V);
- Working temperature: <= 80'C;
- Humidity range: 35%~90%RH (no frost);
- Water pressure: <1.75Mpa;
- Storage temperature: -25~80'C; Storage humidity: 25~95%RH;
- Flow range: 1~5L/min'; Frequency: 4380 pulse for 1L through the sensor
- Dimensions: 2.28 in x 1.38 in x 1.06 in (5.8 cm x 3.5 cm x 2.7 cm)
- Thread Size : G1/4"
YF-S403 water flow sensor 1-30L/min Flow meter
- Model: YF-S403
- The lowest rated working voltage: DC 4.5 5V - 24V.
- Maximum Operating Current: 15 mA (DC 5V).
- Working voltage range: DC 5 - 18V.
- Load capacity: ≤ 10 mA (DC 5V).
- Working temperature: ≤ 80 ℃
- Working humidity range: 35%-90% RH (no frost)
- Allow Pressure: 1.75Mpa
- Storage temperature: -25 - + 80 ° c
- Save Humidity: 25% - 95% RH
- Flow range: 1-30L / min
- External thread: 3/4 "
- Output interface diameter: Ca. Outside 26mm, inside 12mm, 14mm.
- The seal ring with the upper and lower force structure never leaks.
- Non-violent shock, and chemical erosion.
- Non-throwing or hitting.
- Vertical mounting does not exceed 5 degrees inclination.
- The temperature of the medium should not exceed 120 ℃.
- Dimension: 58*35*26 mm
- Weight: 30g

Reviews
There are no reviews yet.