I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
SEN-PPI150 PP Vertical Magnetic Water Level Switch Liquid Level Switch Float Level Switch
₹250.00 Original price was: ₹250.00.₹230.00Current price is: ₹230.00. inc. GST
- Model Number: SEN-PPI150.
- Rated voltage: Below DC24V.
- Installation method: vertical.
- 10W, normally open type.
- Float Ball diameter 24mm
- Fixed Screw M10.
- Switch response time: 0.2ms.
- Colour: white colour.
- Material: Plastic PP.
SEN-PPI150 PP vertical magnetic water level switch design based on a mechanically actuated floating switch used to sense the level of liquid in a tank. These float switches designed to activate electrical components, such as pumps, to start and stop automatically by placing vertically in the water. Due to their high reliability, economical pricing, and easy installation these offer a wide range of applications.
A Float sensor defines as a simple water level indicator. This water level controller used in a pump, an indicator, an alarm, or other devices. It is actually a Magnetic float sensor with an electromagnetic ON/OFF switch that floats on top of a liquid surface. The float switch is to open or close a circuit as the liquid level rises or falls. Float switches designed as “normally opened, condition indicates that the two wires from the top of the switch form a complete circuit.
The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Therefore these Float switch materials designed to resist the deleterious effects of corrosive process liquids. Moreover, the liquid with high viscosity cannot be measured. In case if the pressure inside of the tank is high or the liquid’s specific gravity is low, the float will not operate. So these conditions not permitted for liquid level detection. Normally the float sensor failure occurs due to overloading, frequently caused by spiking voltage.
Note:
- This float sensor installed vertically.
- The installation environment to avoid interference of strong magnetic
- The proximity switch shall not be pressed or dropped
- Avoid being stall in shaking liquid, because the power of dry reed pipe in small power
- Operate with intermediate relay, No direct access to high voltage

Related products
Brass G1/4″ BSP Hall Effect Flow Sensor Water 0.35-3.0L/min OD12 WaterTurbine Flowmeter SEN-HZ41WC
- Water quality requirement: Drinking water health standards, 0-80℃.
- Flow range: 0.35 -0 Liter/min.
- Withstand hydraulic pressure: ≤1.75 MPa.
- Operating voltage: DC 4.5 - 18 Volt
- Operating current: ≤15mA.
- Insulation resistance: >100MΩ.
- Electrical strength: AC500V, 50HZ.
- Output level: Rated voltage DC5V, high level ≥4.5 Volt, low level ≤0.5 Volt.
- Pulse duty cycle: 50%.
- Flow characteristic: F=73Q, F: HZ, Q: L/min,±10%.
- Cumulative flow conversion: 1 Litre water=1780 pulse, accuracy: 8%.
Floating Ball Valve Automatic Float Valve Water Level Control Valve F/ Water Tank Water Tower
- Material: plastic
- Form: diaphragm type
- Connection form: thread
- Drive mode: float control
- Flow direction: one direction
- Nominal diameter:15mm
- Automatic control, less water from the fill, the water from the stop.
- Quarter of the inlet, a large amount of water.
- The appearance of fine, small size, practical, simple installation.
SEN-HZ21WI DN15 1/2 Copper Water Flow Sensor Output Flow Sensor Switch
- Model: SEN-HZ21WI
- Material: Copper
- Colour: Gold
- Type: 1/2(External Thread Diameter)
- Water quality requirement: ≤60℃
- Flow range: 1-30L/min
- Maximum water pressure: 1.75MPa
- Three-wire connection: Red for positive pole, black for negative pole, yellow for pulse signal
- Lightweight, reasonable size, stable performance, low water pressure start, easy to install, safe to use
- Weight: approx. 95g
Side Mounted Small Float Level Control Switch
- Rhodium reed switch
- Special handling reed switches in high temperature
- Overall performance and reliable float switch
- Long-lasting life: Up to 100 million times
- Switch Length: 55 mm
- Cable Length: 300 mm
- Special handling reed switches can make it in 140 ˚C high temperature under normal use
- Overall performance and reliable float switch
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant
YF-S201 ½” Water Flow Sensor
- Model: YF-S201
- Sensor Type: Hall effect
- Working Voltage: 5 to 18V DC
- Max current draw: 15mA @ 5V.
- Output Type: 5V TTL
- Pulses per Litre: 450
- Working Flow Rate: 1 to 30 Liters/Minute
- Accuracy: ±10%
- Maximum water pressure: 2.0 MPa
- Working Temperature range: -25 to +80℃
- Working Humidity Range: 35%-80% RH
- Output duty cycle: 50% +-10%
- Output rise time: 0.04us
- Output fall time: 0.18us
- Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min)
- Durability: minimum 300,000 cycles
- 1/2″ nominal pipe connections, 0.78″ outer diameter, 1/2″ of thread.
- The simple and compact module.
- Easy to Install.
- High Sealing Performance.
- High-Quality Hall Effect Sensor.
YF-S402 High Precision Flow Meter Water Flow Sensor
- Model: YF-S402
- Minimum rated working voltage: DC 5~24V;
- working current: 15mA (DC 5V);
- Working voltage range: DC 5~18V;
- Load capability: <= 10mA (DC 5V);
- Working temperature: <= 80'C;
- Humidity range: 35%~90%RH (no frost);
- Water pressure: <1.75Mpa;
- Storage temperature: -25~80'C; Storage humidity: 25~95%RH;
- Flow range: 1~5L/min'; Frequency: 4380 pulse for 1L through the sensor
- Dimensions: 2.28 in x 1.38 in x 1.06 in (5.8 cm x 3.5 cm x 2.7 cm)
- Thread Size : G1/4"
YF-S403 water flow sensor 1-30L/min Flow meter
- Model: YF-S403
- The lowest rated working voltage: DC 4.5 5V - 24V.
- Maximum Operating Current: 15 mA (DC 5V).
- Working voltage range: DC 5 - 18V.
- Load capacity: ≤ 10 mA (DC 5V).
- Working temperature: ≤ 80 ℃
- Working humidity range: 35%-90% RH (no frost)
- Allow Pressure: 1.75Mpa
- Storage temperature: -25 - + 80 ° c
- Save Humidity: 25% - 95% RH
- Flow range: 1-30L / min
- External thread: 3/4 "
- Output interface diameter: Ca. Outside 26mm, inside 12mm, 14mm.
- The seal ring with the upper and lower force structure never leaks.
- Non-violent shock, and chemical erosion.
- Non-throwing or hitting.
- Vertical mounting does not exceed 5 degrees inclination.
- The temperature of the medium should not exceed 120 ℃.
- Dimension: 58*35*26 mm
- Weight: 30g