- Rating Contract (Max.): 10 W
- Switching Power Supply (Max.): 110VDC
- Pulse current (Max.): 0.5A
- Breakdown Voltage (Max.): 220VDC
- Current (Max.): 1A
- Resistance Contract (Max.): 100 Ω
- Operating Temperature: -10 to 60degree C
- Cable length: 40cm
- Shipment Weight: 0.02 kg
- Float Ball Size : 24×17mm
- Body Total Length: 85mm
- Total Float opening: 70°
- Float Switch ON/OFF angle: Approx. between 15° to 20°
The Anti-Corrosion Water Level Sensor with Ball Float Switch is designed specifically to sense the level of liquid within a tank. This Sensor for Water Level Controller design based on a mechanically actuated floating switch. These float switches are designed to activate electrical components, such as pumps, to start and stop automatically. Due to their high reliability, economical pricing, and easy installation these offer a wide range of applications. This module is available with Counterweights and cable hangers to suit perfectly a variety of mounting applications.
A Float sensor defines as a simple water level indicator. This water level controller is used in a pump, an indicator, an alarm, or other devices. The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Thus the Float switch materials are designed to resist the deleterious effects of corrosive process liquids. In most of the systems, a properly selected and sized float detects the interface level between two liquids of different densities. Therefore, this Cable Float Switch is mainly used for the automatic working of small pumps with a cable length of 40cm. Here the Float Ball Size measures 24×17mm with a float switch ON/OFF angle between 15° to 20°.
Moreover, this anti-corrosive water level sensor is widely used in hydroponics, saltwater tank, freshwater tank, gardening, aquariums for power head control, pet bowls, fish tanks, filtration, heating, or whatever your project may be.

Related products
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Â Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Â The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- -Â Â Â Ambient temperature : -20 ~ +55
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 95% RH
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Environmental oxygen content: 21%
- Storage conditions :
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Temperature : -20 ~ +70
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 33±10%
- Â Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit
RCWL-0516 Microwave Radar Sensor
- Operating Voltage: 4 to 28 V DC
- Operating Current: 2.8mA (typical); 3mA (max)
- Detecting Range: 5-9m
- Transmitting Power: 20mW (typical); 30mW (max)
- Output Voltage: 3.2 to 3.4v
- Output Voltage Driving Capacity: 100mA
- Output Control Low Level: 0V
- Output Control High Level: 3.3V
- Operating Temperature (C): -20 to 80 degree C
- Transmission signal processing control chip RCWL-9196
- Penetrating detection capability, compared with the traditional infrared feeling PIR
- Adjustable Block time and distance
- Dimension:36*17*2mm
- Weight: 3gm