I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
EMG Sensor / Muscle Sensor Module For Arduino
₹3,000.00 Original price was: ₹3,000.00.₹2,600.00Current price is: ₹2,600.00. inc. GST
- Power Supply: Normally ±9V dual power supply, the minimum voltage is ±3.5V
- The diameter of the Electrode Pad: 52 mm
- Cable Length: 2 feet
- Improved adjustable gain (more rugged)
- 5mm connector
- On-board port for new cables Connects to the board straight out of the box
- Supported with Arduino, Breadboard mountable
- Weight: 30gm.
Electromyography (EMG) sensor is defined as muscle response or electrical activity measuring device in response to a nerve’s stimulation of the muscle. The test was employed to detect neuromuscular abnormalities. During the test, one or more small electrode needles are inserted through the skin into the muscle. The electrical activity achieved by the electrodes is further displayed on an oscilloscope (a monitor that displays electrical activity within the sort of waves). An audio-amplifier is employed therefore the activity is often heard. The electrical activity of muscle is measured during rest, slight contraction, and forceful contraction. Muscle tissue doesn’t normally produce electrical signals during rest. When an electrode is inserted, a quick period of activity is often seen on the oscilloscope, but then, no signal should be present.
After an electrode is inserted, you should contact the muscle, for instance, lifting or bending your leg. The nerve impulse on the oscilloscope provides information about the power of the muscle to reply when the nerves are stimulated. When more muscles contract forcefully, more and more muscle fibres are activated, thereby producing action potentials.
Using a cable and electrodes muscle sensor measures filters, rectify, and amplifies the electrical activity of a muscle and produces an analogue output signal. A microcontroller, enabling novel, muscle-controlled interfaces for your projects, can easily read these signals. It outputs Depending on the amount of activity in the selected muscle, it outputs signal 0-Vs Volts, where Vs signifies the voltage of the power source. It operates at a minimum Power supply voltage of +-3.5V. The impulse on the oscilloscope provides information about the power of the muscle to reply when the nerves stimulate.

Related products
16 CHANNEL 12V RELAY
- 16 channel 12V relay board
- Operating voltage: 12V
- Supply current: 0.2 A
- Relay contact current capacity of 10A @250 V AC/10A@ 30V AC
- Optocoupler protection
- LED status indicates relay ON/OFF state.
- The 10-16 road can be any full-on/off or any road
- Common terminal(com) in each rely is user friendly and can be accessed by different signal
- Normally closed or normally open with each port
- Strong anti-jamming ability and stable performance
- The on-board power supply module doesn’t need any external power
- Dimension: 180*90*20mm
- Weight: 100gm
2 CHANNEL 5V RELAY
- High current relay
- Two LED S to indicate relays ON/OFF status
- Low-level trigger expansion board
- Opto isolation circuitry
- Works with logic level signal 3.3V or 5V devices
- Can be used as normally open (NO) or normally closed (NC)
- Back EMF protection
- Ensures diode current protection
- AC control voltage: 250v @mx10A
- DC control voltage: 30V @max 10A
- Easy installation and fixing
AC-DC Power Module HLK-5M05 230V to 5V /5W
- Meet UL, CE requirements
- Rated input voltage: AC 100V -230V
- Input voltage range: 90V -264V AC
- Maximum input current: <0.2A
- Input current surge: <10A
- Maximum input voltage: <270V AC
- Input Low Voltage Efficiency: Vin=110V AC,Output full-load≥ 69%
- Input High Voltage Efficiency: Vin=220V AC,output full-load≥ 70 %
- Long-term reliability
- Voltage Regulation: ±0.2%
- Load Regulation: ±0.5%
- Ultra-thin and small module
- High efficiency, high power density
- Low ripple and low noise
- Output overload and short circuit protection
- Working temperature: – 20 degrees to +60 degrees Celsius
- Storage temperature: -40 degrees to 80 degrees Celsius
- Relative humidity: 5-95%
- Cooling way: Natural cooling
- Atmospheric pressure: 80-106Kpa
- Weight: 21g
- Size: 38x23x18mm
AC-DC Power Module HLK-PM01 230V to 5V /3W
- Meet UL, CE requirements
- Rated input voltage: AC 100V -230V
- Maximum input voltage: <270V AC
- Voltage Regulation: ±0.2%
- Load Regulation: ±0.5%
- High efficiency, high power density
- Ultra-thin and small module
- Low ripple and low noise
- Output overload and short circuit protection
- 100% load ageing and testing
- The product is designed to meet the requirements of the EMC and Safety Test
- Low power consumption, environmental protection, no-load loss <0.1W
- High efficiency, high power density
- Working temperature: – 20 degrees to +60 degrees Celsius
- Storage temperature: + 80-40 -degree
- Relative humidity: 5-95%
- Cooling way: Natural cooling
- Atmospheric pressure: 80-106Kpa
- Weight: 21g
- Size: 38x23x18mm
AC-DC Power Module HLK-PM03 230V to 3.3V /3W
- Meet UL, CE requirements
- Rated input voltage: AC 100V -230V
- Input voltage range: 90V -264V AC
- Maximum input current: <0.2A
- Input current surge: <10A
- Maximum input voltage: <270V AC
- Input Low Voltage Efficiency Vin=110V AC,Output full-load≥ 69%
- Input High Voltage Efficiency Vin=220V AC,output full-load≥ 70 %
- Long-term reliability
- Voltage Regulation: ±0.2%
- Load Regulation: ±0.5%
- Ultra-thin and small module
- High efficiency, high power density
- Low ripple and low noise
- Output overload and short circuit protection
- Working temperature: – 20 degrees to +60 degrees Celsius
- Storage temperature: -40 degrees to 80 degrees Celsius
- Relative humidity: 5-95%
- Cooling way: Natural cooling
- Atmospheric pressure: 80-106Kpa
- Weight: 21g
- Size: 38x23x18mm
AC-DC Power Module HLK-PM12 230V to 12V /3W
- Rated input voltage: AC 100V -230V
- Input voltage range: 90V -264V AC
- Maximum input current: <0.2A
- Input current surge: <10A
- Maximum input voltage: <270V AC
- Input Low Voltage Efficiency Vin=110V AC,Output full-load≥ 69%
- Input High Voltage Efficiency Vin=220V AC,output full-load≥ 70 %
- Short-term maximum output current: ≥1000 mA
- Long-term reliability
- Voltage Regulation: ±0.2%
- Load Regulation: ±0.5%
- Ultra-thin and small module
- High efficiency, high power density
- Low ripple and low noise
- Output overload and short circuit protection
- Working temperature: – 20 degrees to +60 degrees Celsius
- Storage temperature: -40 degrees to 80 degrees Celsius
- Relative humidity: 5-95%
- Cooling way: Natural cooling
- Atmospheric pressure: 80-106Kpa
- Weight: 21g
- Size: 38x23x18mm
ADXL345
- Supply voltage: 3.3V/5V
- Communication type: I2C/SPI
- Sensing range: +/-2G to +/-16G
- Sensitivity
- X: 28.6 LSB/G
- Y: 31.2 LSB/G
- Z:34.5 LSB/g
- On-board LDO voltage regulator
- Resolution: 13 bit
- Single tap/double-tap detection
- Embedded memory management system with FIFO
- 10000g shock survival
- Low power consumption as low as 23 µA in measurement mode and 0.1 µA in standby mode at VS = 2.5 V (typical)
- 3-axis MEMS accelerometer
- Ideal for noisy power environment
- Operating temperature: -40 degrees to 85 degrees Celsius
- Dimension: 28*14mm
I2C MODULE WITH 16*2 CHARACTER LCD
- Supply voltage: 5V
- Display mode: STN
- Display format: 16*2
- Input data: 4 bit or 8 bit (for LCD)
- I2C address: 0x20~0x27 (original address is 0x20,we can change it ourselves)
- Compatible with multiple communication logic levels: 2.8~5VDC
- Compatible for 16*2 LCD
- Serial I2C control of LCD display using PCF8574
- Allow data display via only 2 wires.
- Backlight and contrast adjustment by the potentiometer
- Supports 7 ASCII fonts, 5 graphic functions
- Supports 128 level backlight lightness adjustment.
- Support 64 level screen contrast adjustment
- Supports device address modification
- Dimension: 10*4*5cm
- Size: 150gm