I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
HCZ-H8-B Humidity Sensor, HCZ Series, 20% to 90% RH, 3 %, Through Hole, No Housing
- The rated voltage is 1Vrms
- Operating frequency ranges from 0.5KHz to 2KHz
- Operating temperature range from 0°C to 60°C
- Operating humidity range from 20%RH to 90%RH
- Rated power of 0.2mW
- Humidity accuracy range from -3%RH to +3%RH
- Available without housing
This HCZ-H8-B humidity sensor was designed by Multicomp. This humidity sensor is widely used in air conditioners, humidifiers, dehumidifiers, hygrometers, recorders, the transmitter for relative humidity measurement, control, and display. The terminal electrode of HCZ-H8-B uses lead-free solder material such as Sn / Ag / Cu. This product was designed in conformity with the RoHS directive. This Indicates that lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants were not used. Thus this sensor offers highly precise, more accurate, and works in a bigger range of humidity.
HCZ-H8-B humidity sensor Module features Small size & low consumption & long transmission distance makes it ideal for all kinds of application occasions. Moreover, this sensor offers a better humidity measuring range, from 20%RH to 90%RH with -3%RH to +3%RH accuracy. This module operates at a rated voltage of 1Vrms at a rated power of 0.2mW. It measures the surrounding air and outputs a digital signal on the data pin (no analogue input pins are needed). Thus it is quite simple to use but requires careful timing to grab data.

Related products
DHT22 Sensor
E-18-D80 NK Infrared sensor
- Model: E18-D80NK
- Input voltage: 5VDC
- Sensing range: 3 – 80cm
- Current Consumption: 300mA.
- Cable length: 1 m.
- Current: 100mA
- Pointing Angle: ≤ 15
- Appearance: threaded cylindrical
- Diameter: 18mm
- Length: 45mm
- Detection of object: transparent or opaque
- Output operation: normally open
- Diameter: 17MM
- Reverse polarity protection
- Digital Output.
- Can detect colour differences from a certain range.
- TTL output is low whenever the sensor senses an obstacle.
- External control circuit unnecessary.
- Diffuse reflective type.
- Low consumption.
- Operating temperature: -25℃ to 55℃
- Material: plastic
- Red: +5V; Yellow: Signal; Green: GND
Force Sensor 38.1mm
- Easily customizable to a wide range of sizes
- Cost-effective
- Ultra-thin; 0.45 mm
- Life: up to 10 million actuations
- Simple and easy to Integrate.
- Actuation Force: 0.1 Newtons
- Force Sensitivity Range: 0.1 - 10.02 Newtons
- Non-Actuated Resistance: 10M W
- Device Rise Time: <3 microseconds
- Temp Operating Range: 30 - +70 ºC
- 16MHz Clock Speed
- 32 KB Flash Memory
- Overall length: 1.75 inches
- Overall width: 0.28 inch
- Sensing area: 0.3 inch
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ7 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Can detect the presence of carbon monoxide
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating time (high): 60 ± 1 seconds
- Heating time (low): 90 ± 1 seconds
- Heating consumption: About 350mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: Less than 95%RH
- Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
- Stable, long life and low cost
- Good sensitivity to Combustible gas in a wide range
MQ8 GAS SENSOR
- Operating Voltage: 3.3 – 5V.
- Type: Analog Sensor.
- Detection range: 100~1000ppm(H2 gas)
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 31Ω ± 5%
- Heating consumption: less than 800mW
- Using temperature: -20°C-50°C
- Storage temperature: -20°C-50°C
- Relative humidity: 55%+-5%RH
- High Sensitivity for Hydrogen
- Small sensitivity to alcohol, LPG, cooking fumes
Soil Moisture Sensor
- Operating voltage: 3.3V to 5V Operating Current: 5mA.
- Dual output mode, analogue output and digital output
- Analogue output is more accurate
- Fixed bolt hole for easy installation
- Onboard power indicator (red) and digital switching output indicator (green)
- LM393 comparator chip
- Panel PCB Dimension: Approx.3cm x 1.5cm
- Soil Probe Dimension: Approx. 6cm x 3cm
- Cable Length: Approx.21cm
- Dimensions: 98 x 23 x 4.mm
- Weight (gm): 15
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews