Water Float Sensor P43
₹200.00 Original price was: ₹200.00.₹175.00Current price is: ₹175.00. inc. GST
- Color: White & Yellow
- Cable Length: 30.5(cm)
- Maximum Load: 50 W
- Max Switching Voltage: 100V DC
- Minimum Voltage: 250V DC
- Maximum Switching Current: 0.5 A
- Max Load Current: 1.0 A
- Max Contact Resistance: 0.4 Ω
- Temp Rating: -20~ 80 degree
- Weight: 10g
A Float sensor defines as a simple water level indicator. This water level controller used in a pump, an indicator, an alarm, or other devices. A water level controller is actually a Magnetic float sensor with an electromagnetic ON/OFF switch that floats on top of a liquid surface. The float switch is to open or close a circuit as the liquid level rises or falls. Float switches are “normally closed, condition indicates that the two wires from the top of the switch form a complete circuit.
This float sensor consists of a magnetic reed switch to open or close the circuit. The reed switch is designed to enclosed in a glass tube, cemented into a plastic or stainless steel stem with epoxy. When the magnet comes in contact with each other allowing the current to pass through. As soon as the magnet moved away, the contacts demagnetize and separate, thus breaks the circuit,
The float switch installations reduce the chance for the accumulation of dirt on the float that would prevent its motion. Therefore these Float switch materials designed to resist the deleterious effects of corrosive process liquids. In most of the systems, a properly selected and sized float detects the interface level between two liquids of different densities.
Moreover, the liquid with high viscosity cannot be measured. In case if the pressure inside of the tank is high or the liquid’s specific gravity is low, the float will not operate. So these conditions not permitted for liquid level detection. Normally the float sensor failure occurs due to overloading, frequently caused by spiking voltage.
Applications:
- Water Vending Machines
- Coffee Vending Machines
- Juice vending Machines

Related products
DN40 – 1.5” Water Flow Sensor
- Model: YF-DN40
- Material: Plastic
- Function: Sensor, flow rate control
- Working Voltage: DC 5V~24V
- Thread size: BSP 1 1/2”
- Size:L 92x OD46 5"
- Colour: Black color
- Flow rate: 5~200L/min
- Flow Pulse: F(Hz)=(0.45xQ) +/-3% Q=L/min
- 1L water= 27Pulse
- Working Current: 15mA (DC5 V)
- Working Voltage: DC 4.5V
- Load Capacity: =10 mA (DC 5 V)
- Operating Working Temperature: -25 to +80 Degree C
- Liquid Temperature: 85
- Accuracy: 3~5%
- Working environment: water, liquid, light oil etc.
- Hydrostatic pressure> 1.75MPa meet
- Insulation resistance> 100M> 100M
- Accuracy in 1 ~ 120L / MIN ± 2% in line
- Flow pulse characteristics F = (0.45 * Q) Q = L / Min meet
- Weight: 146g
FLOAT SWITCH
FLOAT SWITCH BLACK VERTICAL
Floating Straight Automatic Water Level Control For Water Tank-14014449MG
- Automatic Control, Low Self-Complementary Water, Water Full Automatic Stop.
- Four Intakes, Large Volume Of Water.
- Beautiful Appearance, Small Size, Practical, Simple Installation.
- Without Electricity, Easy To Use, Long Life, Low Failure Rate, Saving Water Resources.
- Working Pressure Range: 0.2-10Kg.
- Applicable Medium: Clean Water.
- Applicable Medium Temperature: ≤70degree C
- Resistance to High-Temperature to Medium Temperature: 70degree to 120degree C
- Material: Nylon Pa66, Stainless Steel Screws, Food Grade Rubber.
- Diameter: Approx. 46Mm / 1.81Inch.
- Dimension: Approx. 83*71mm
G3/4 Thread Water Flow Sensor Switch Control Meter Flowmeter 1-30L/min SEN-HZ43WB
- Water quality requirement: Drinking water health standards, 0-80℃
- Flow range: 2-45 Liter/min
- Withstand hydraulic pressure: ≤1.75 MPa
- Voltage/electric current: DC 4.5 - 18 Volt , ≤15mA
- Insulation resistance: >100MΩ
- Electrical strength: AC500V, 50HZ
- Output level: Rated voltage DC 5 Volt, high level ≥4.5 Volt, low level ≤0.5 Volt
- Pulse duty cycle: 50%
- Flow characteristic: F=8.1Q-3, F: HZ, Q: L/min,±10%
- Cumulative flow conversion: 1 Liter water=477 pulse, accuracy: 10%
Water Lifting Pump
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant
YF-S201 ½” Water Flow Sensor
- Model: YF-S201
- Sensor Type: Hall effect
- Working Voltage: 5 to 18V DC
- Max current draw: 15mA @ 5V.
- Output Type: 5V TTL
- Pulses per Litre: 450
- Working Flow Rate: 1 to 30 Liters/Minute
- Accuracy: ±10%
- Maximum water pressure: 2.0 MPa
- Working Temperature range: -25 to +80℃
- Working Humidity Range: 35%-80% RH
- Output duty cycle: 50% +-10%
- Output rise time: 0.04us
- Output fall time: 0.18us
- Flow rate pulse characteristics: Frequency (Hz) = 7.5 * Flow rate (L/min)
- Durability: minimum 300,000 cycles
- 1/2″ nominal pipe connections, 0.78″ outer diameter, 1/2″ of thread.
- The simple and compact module.
- Easy to Install.
- High Sealing Performance.
- High-Quality Hall Effect Sensor.