Showing 61–72 of 110 results

MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module

₹200.00 inc. GST
  • Input voltage: DC 5V
  • Power: 150mA
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
  • Suitable for home or factory gas leakage monitoring devices.
  • Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
  • High quality dual-panel design, with power indicator and TTL signal output instructions.
  • DO switching signal (TTL) output and AO analog signal output.
  • TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
  • Analog output voltage: the higher concentration, the higher voltage.
  • Four screw holes, easy positioning.
  • Long life and stability, quick response and resume.

MQ135 SENSOR

₹180.00 inc. GST
  • Operating Voltage: 3.3 – 5V.
  • Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
  • Analog output voltage: 0V to 5V
  • Digital output voltage: 0V or 5V (TTL Logic)
  • Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
  • Heating voltage (high): 5V ± 0.1
  • Heating voltage (low): 1.4V ± 0.1
  • Load resistance: Adjustable
  • Heating resistance: 33Ω ± 5%
  • Heating consumption: less than 800mW
  • Detection temperature: 20℃±2℃
  • Relative humidity: 65%+-5%RH
  • Preheat duration 20 seconds
  • Can be used as a digital or analogue sensor
  •  The sensitivity of Digital pin can be varied using the potentiometer
  • It has a long life and low cost.
  • Possesses high sensitivity to ammonia, benzene, sulfide gases.
  • simple drive circuit

MQ2 Sensor

₹150.00 inc. GST
  • Operating Voltage: +5V
  • Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
  • Analogue output voltage: 0V to 5V
  • Digital Output Voltage: 0V or 5V (TTL Logic)
  • Preheat duration 20 seconds
  • Can be used as a digital or analogue sensor
  • Load resistance: 20 KΩ
  • Heater resistance: 33Ω ± 5%
  • Heating consumption: <800mw
  • Sensing Resistance: 10 KΩ – 60 KΩ
  • Detection range: 200 – 10000ppm
  • Preheat Time: Over 24 hour
  • High sensitivity to LPG, Propane, and Hydrogen
  • The Sensitivity of a Digital pin can be varied using the potentiometer

MQ3 Sensor

₹200.00 inc. GST
  • Operating Voltage: 5V ±0.1
  • Detecting Concentration: 0.05-10mg/L Alcohol
  • Current Consumption : 150mA
  • Operation Temperature : -10°C ~ 70°C
  • Heater consumption: less than 900mW
  • Load resistance: Adjustable
  • Heating resistance: 33Ω ± 5%
  • Easy SIP header interface
  • Compatible with most of the microcontrollers
  • Low-power standby mode
  • Requires heater voltage
  • Good sensitivity to alcohol gas
  • Fast response and High sensitivity
  • Requires simple Drive circuit
  • Dimensions: 32 x 22 x 16 mm

MQ303 Sensor

₹360.00 inc. GST
  • Gas: Alcohol ( ethanol )
  • Detection range : 20 to 1000ppm
  • Characteristics of gas: 125ppm alcohol
  • Sensitivity: R in air / Rin typical gas 3
  • Sensing Resistance: 4 to 400K in air atmosphere
  • Response time : 10s (70% Response)
  • Recovery time : 30s (70% Response)
  • Heating resistor: 4.5 Ω ± 0.5 Ω
  • Heating current: 130mA
  • Heating voltage : 0.9V ± 0.10V
  • Heating power: 130mW
  • Measure the voltage: 24V
  • concentration range: 20 to 10,000 ppm
  • Working conditions :
  • -    Ambient temperature : -20 ~ +55
  •                     -    Humidity: 95% RH
  •                     -    Environmental oxygen content: 21%
  • Storage conditions :
  •                      -    Temperature : -20 ~ +70
  •                      -    Humidity: 70% RH
  • High sensitivity
  • Fast response and resume
  • Long life and low cost
  • For ethanol, vapour has high sensitivity and good selectivity
  • Simple drive circuit
  • Dimensions: 60mm x90mm x9mm
  • Weight: 5g

MQ4 Sensor

₹150.00 inc. GST
  • Power requirements: VCC - 5V±0.1
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
  • Detection Gas: Natural gas/Methane
  • Detection Concentration: 200-10000ppm (Natural gas / Methane)
  • Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
  • Heater consumption: less than 750mw
  • Operating temperature: 14 to 122 °F (-10 to 50°C)
  •  Related humidity less than 95%Rh
  • Load resistance: 20KΩ
  • Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
  • Preheat time: Over 24 hour
  • Standard Encapsulation Bakelite, Metal cap

MQ5 SENSOR

₹150.00 inc. GST
  • Power requirements: VCC - 5V±0.1
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
  • Detection Gas: LPG, natural gas, town gas
  • Detection Concentration: 300-10000ppm
  • Heating voltage: 5V±0.1
  •  Load resistance: 20KΩ
  •  Heater resistance: 31±10%
  •  Heating consumption: less than 800mw
  • Operating temperature:-10 to 50°C
  • Related humidity less than 95%Rh
  • Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
  • Preheat time: Over 24 hour

MQ6 SENSOR

₹150.00 inc. GST
  • Power requirements: VCC - 5V±0.1
  • DO output: TTL digital 0 and 1 (0.1 and 5V)
  • AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
  • Detection Gas: LPG, iso-butane, propane, and LNG
  • Detection Concentration: 200-10000ppm
  • Heating voltage: 5V±0.1
  •  Load resistance: 20KΩ
  •  Heater resistance: 33±10%
  •  Heating consumption: less than 750mw
  • Operating temperature:-10℃-50℃
  • Related humidity less than 95%Rh
  • Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
  • Preheat time: Over 24 hour
  • High sensitivity to LPG, iso-butane, propane
  • Small sensitivity to alcohol, smoke.
  • Fast response
  • Simple drive circuit

MQ7 GAS SENSOR

₹175.00 inc. GST
  • Operating Voltage: 3.3 – 5V.
  • Type: Analog Sensor.
  • Can detect the presence of carbon monoxide
  • Heating voltage (high): 5V ± 0.1
  • Heating voltage (low): 1.4V ± 0.1
  • Load resistance: Adjustable
  • Heating resistance: 33Ω ± 5%
  • Heating time (high): 60 ± 1 seconds
  • Heating time (low): 90 ± 1 seconds
  • Heating consumption: About 350mW
  • Using temperature: -20°C-50°C
  • Storage temperature: -20°C-50°C
  • Relative humidity: Less than 95%RH
  • Oxygen concentration: 21%(stand condition) the oxygen concentration can affect the sensitivity characteristic
  • Stable, long life and low cost
  • Good sensitivity to Combustible gas in a wide range

MQ8 GAS SENSOR

₹175.00 inc. GST
  • Operating Voltage: 3.3 – 5V.
  • Type: Analog Sensor.
  • Detection range: 100~1000ppm(H2 gas)
  • Heating voltage (high): 5V ± 0.1
  • Heating voltage (low): 1.4V ± 0.1
  • Load resistance: Adjustable
  • Heating resistance: 31Ω ± 5%
  • Heating consumption: less than 800mW
  • Using temperature: -20°C-50°C
  • Storage temperature: -20°C-50°C
  • Relative humidity: 55%+-5%RH
  • High Sensitivity for Hydrogen
  • Small sensitivity to alcohol, LPG, cooking fumes

Photo Control Sensor Automatic Street Lighting Switch Photocell Photoswitch

₹300.00 inc. GST
  • Input Voltage:220V AC
  • Max Load Current: 10A
  • Frequency: 50-60Hz
  • Colour: White & Blue
  • Intelligent Sensor Light Control Switch
  • The light turns on in the dark and turn off in the daytime, an intelligent sensor, no need to operate by manual.
  • Widely use in streets, high-speed expressways, factories, gardens, airports, farms, schools and other places.
  • Dimension: 5 x 4.2 x 3.3cm

PIEZO Vibration Sensor

₹400.00 inc. GST
  • Flexible PVDF Piezo Polymer Film
  • Flex, Touch, Vibration and Shock measurements
  • Voltage Sensitivity (open-circuit, baseline): 1.1 V/g.
  • Charge Sensitivity (baseline): 260 pC/g.
  • Upper Limiting Frequency (+3 dB): 42 Hz.
  • Resonance Frequency: 75 Hz.
  • Voltage Sensitivity (open-circuit, at resonance): 6 V/g.
  • Wide dynamic range:001Hz~1000MHz
  • Laminated for higher voltage output
  • Breadboard friendly leads.
  • Standard grove socket
  • Adjustable sensitivity
  • Withstands High Impact
  • Operating Temperature: 0ºC to 85ºC
  • Storage Temperature: -40ºC to 85 ºC
  • Dimensions: 6.9 x 3.9 x 0.8 cm