I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Load Cell CZL 601 40KG
₹500.00 Original price was: ₹500.00.₹450.00Current price is: ₹450.00. inc. GST
- Material: Aluminium alloy
- Rated load: 40KG
- Comprehensive error: 0,03% F.S.
- Rated output: 2±0.02mV/V
- Repeatability : 0.01% Full scale
- Zero Balance : +/- 1% Full scale
- Excitation Voltage: 9~12V
- Safe Load: 120% of Rated Capacity
- Ultimate Load: 150% of Rated Capacity
A load cell transducer/sensor generates an electrical signal whose magnitude is directly proportional to the force measured. The standard straight bar load cell 40kg (sometimes called a strain gauge) translates up to 40 kg of pressure (force) into an electrical signal. Each load cell 40kg measures the electrical resistance that changes is proportional to the strain (e.g. pressure or force) applied to the bar. The output of the load cell is in milli-volts and cannot be directly measured by a micro-controller. So an ADC with high resolution or an instrumentation amplifier reads the output of the load cell to the microcontroller.
The intensity of deformity defines how much force is applied, and this value is digitally sent to an interface module. This gauge can determine how heavy an object is, whether the object’s weight changes over time or if you simply need to sense the object by measuring strain or load applied to a surface. This straight bar load cell is made from an aluminium alloy. And it is capable of reading a capacity of 40KG of weight. These load cells also provide an IP65 protection rating for the sensor.
Here each load cell consists of four strain gauges connected into a Wheatstone bridge. Wheatstone bridge is basically two potential dividers connected in parallel. Here SG1 and SG2 form one of the potential divider circuits. Similarly, SG3 and SG4 form the other divider circuit. Output voltage for the load cell taken from the midpoint of the potential divider circuits. Therefore, when strain is applied to the bridge, the gauge measures the strain as an electrical signal, because the strain changes the electrical resistance of the wire.

Related products
GP2Y0A21YK0F 10-80cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 10 cm to 80 cm
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: : 29.5×13×13.5 mm
- Weight: 3.5 gm
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
LDR SENSOR 20mm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ135 SENSOR
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm Alcohol
- Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Â The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- -Â Â Â Ambient temperature : -20 ~ +55
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 95% RH
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Environmental oxygen content: 21%
- Storage conditions :
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Temperature : -20 ~ +70
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews
There are no reviews yet.