- Operating Voltage: 5V ±0.1
- Detecting Concentration: 0.05-10mg/L Alcohol
- Current Consumption : 150mA
- Operation Temperature : -10°C ~ 70°C
- Heater consumption: less than 900mW
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Easy SIP header interface
- Compatible with most of the microcontrollers
- Low-power standby mode
- Requires heater voltage
- Good sensitivity to alcohol gas
- Fast response and High sensitivity
- Requires simple Drive circuit
- Dimensions: 32 x 22 x 16 mm
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ3 sensor also known as Alcohol gas sensor ideal for the detection or measuring of Alcohol, Benzine, CH4, Hexane, LPG, CO. It offers very good sensitivity and a fast response time makes it ideal such as used in gas leakage alarm systems. The MQ3 sensor operates at a voltage of 5V DC and draws around 900mW. It provides a lower conductivity to clean the air as a gas sensing material.
MQ3 sensor is a Tin oxide semiconductor sensor designed explicitly to detect Alcohol concentration from 0.05 mg/L to 10 mg/L.  It offers very good sensitivity and fast response to alcohol. When the target gas contains the content of alcohol, the sensor’s conductivity is higher alongside the gas concentration rising. As MQ3 gas sensor offers high sensitivity to Alcohol and has good resistance to disturb of gasoline, smoke, and vapour. This sensor provides an analogue resistive output supported alcohol concentration and digital output.
The resistance varies inside the sensor on the detection of alcohol. Therefore more the alcohol content exhibits the lower the resistance. Thus the alcohol content is measured by measuring this resistance. As a result, the sensor and load resistor in the module form a potential divider, and therefore the lower the sensor resistance, the upper the voltage reading is going to be.
Applications:
- Gas level over-limit alarm
- Breathalyzer
- Portable alcohol detector
- Stand-alone/background sensing device
- Environmental monitoring equipment

Related products
Force Sensor 14.7MM
GP2Y0A21YK0F 10-80cm
- Model: GP2Y0A21YK0F
- Operating Voltage Range: 4.5~5.5V
- Average current consumption: 30 mA
- Distance measuring range: 10 cm to 80 cm
- Output type: Analog voltage
- Output voltage differential over distance range: 2.05 V (typical)
- Update period: 38 ± 10 ms
- Screw Holes: 37mm apart, 3 mm in diameter
- Connecting cable length:15cm
- Very Small in size
- Less influence on the colour of reflected objects, reflectivity
- Analogue voltage corresponding to the voltage
- External control circuit unnecessary
- Low cost
- The sampling rate of nearly 25 readings per second
- Dimension: : 29.5×13×13.5 mm
- Weight: 3.5 gm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- -Â Â Â Ambient temperature : -20 ~ +55
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 95% RH
- Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Environmental oxygen content: 21%
- Storage conditions :
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Temperature : -20 ~ +70
- Â Â Â Â Â Â Â Â Â Â Â -Â Â Â Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ4 Sensor
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
- Â Related humidity less than 95%Rh
- Load resistance: 20KΩ
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
- Standard Encapsulation Bakelite, Metal cap
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 31±10%
- Â Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
MQ6 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, iso-butane, propane, and LNG
- Detection Concentration: 200-10000ppm
- Heating voltage: 5V±0.1
-  Load resistance: 20KΩ
-  Heater resistance: 33±10%
- Â Heating consumption: less than 750mw
- Operating temperature:-10℃-50℃
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm LPG)
- Preheat time: Over 24 hour
- High sensitivity to LPG, iso-butane, propane
- Small sensitivity to alcohol, smoke.
- Fast response
- Simple drive circuit