I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
SHARP Air detection sensor dust sensor GP2Y1010AU0F KG017
₹750.00 Original price was: ₹750.00.₹499.00Current price is: ₹499.00.
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
GP2Y1010AU0F sensor also known as optical air quality sensor used to Sense Dust Particles. This compact-sized optical sensor consists of works by detecting the reflected light of dust in the air. It is an ideal solution to detect very fine particles like cigarette smoke. Moreover, it also determines the smoke from house dust by pulse pattern of output voltage, thus commonly used in air purifier systems. The sensor features very low current consumption (20mA max, 11mA typical), and can be powered with up to 7VDC. The output of the sensor is an analogue voltage proportional to the measured dust density, with a sensitivity of 0.5V/0.1mg/m3. GP2Y1010AU0F sensor operates at a voltage range of 4.5V to a maximum of 5.5V DC supply voltage.
GP2Y1010AU0F dust sensor consists of an infrared emitting diode and a phototransistor diagonally arranged into this device system. This works on the principle of Laser Scattering. Therefore the Infrared emitting diode in the sensor illuminates the particles in the air that enters through the air inlet. And this scattered light is transformed into a form of the signal by a phototransistor. Further, the amplifier circuit amplifies these signals and is then processed to obtain the particle concentration. The intensity of the scattered light depends on the dust particles.
The more the dust particles in the air, the greater will be the intensity of light. Thus the Output voltage at the VOUT pin of the sensor varies according to the intensity of scattered light. Moreover, this module offers a wide range of applications in dust removal equipment alarm equipment, air purification equipment, dust robots, fire alarm, etc.

Related products
BMP280 Pressure Sensor module High Precision Arduino
- Chip:BMP280
- Operating Voltage: 1.71V to 3.6V
- Communication method: Standard IIC/SPI communication protocol
- Pin pitch: 2.54mm
- Operating Temperature: -40 to +85 deg. Celsius
- Operating Pressure: 300 hPa to 1100 hPa
- Peak current: 1.12mA
- Current consumption: 2.7µA @ 1 Hz sampling rate
- Accuracy between( 700 to 900hPa and 25 to 40 deg. C): ±0.12hPa and ±1.0m
- Package 8-pin LGA metal-lid
- Relative accuracy(950 … 1050hPa @25°C): ±0.12 hPa, equiv. to ±1 m
- RoHS compliant, halogen-fre
- Module size: 11.5mm*15mm
GP2Y1010AU0F Optical Dust Sensor
- Operating Voltage: 4.5V to 5.5V
- Low Current Consumption: 20mA max
- Sensitivity: 0.5V/(0.1mg/m3)
- Clean-air voltage: 0.9V typical
- Storage temperature:-20 ~80 degrees Celsius
- Minimum Detectable Dust Size: 0.5µm
- Smallest particles detected value: 0.8 micron
- Dust Density Sensing Range: Up to 580 µg/m3
- Sensing Time: Less than 1 Second
- Service life: 5 years
- The presence of dust can be detected by the photometry of only one pulse
- Enable to distinguish smoke from house dust
- Lead-free and RoHS directive compliant
- Operating temperature:-10 -65 degrees Celsius
- Dimensions: 46.0 x 30.0 x 17.6 mm
- Weight: 15gm
Induction Cooker Sensor
LJ12A3-4-Z/BY PNP DC6-36V 8 mm INDUCTIVE PROXIMITY SENSOR
- Output type: PNP NO
- Supply voltage: 6V-36V
- Current output: 300mA
- Response frequency: 0.5khz
- Detecting distance: 4mm
- Wire type: cylindrical DC 3 wire type
- Switch appearance type: cylinder type
- Operating temperature: -25 degrees to 55 degrees Celsius
- Detect object: iron
- Red led checks proximity status
- High repeated positioning accuracy
- High switching frequency
- Reverse power protection, short circuit protection, directly connecting with PLC
- anti-vibration, dust, water, and oil prevention
- Dimension: 5*3*3cm
- Weight: 400gm
MQ-9 Carbon Monoxide, Methane and LPG Gas Sensor Module
- Input voltage: DC 5V
- Power: 150mA
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0.3V (relatively clean), the highest concentration voltage is about 4V.
- Suitable for home or factory gas leakage monitoring devices.
- Have better sensitivity to Carbon Monoxide, Methane and LPG Gas.
- High quality dual-panel design, with power indicator and TTL signal output instructions.
- DO switching signal (TTL) output and AO analog signal output.
- TTL output valid signal is low. (When the output low signal is on, it can be directly connected micro-controller or relay module.)
- Analog output voltage: the higher concentration, the higher voltage.
- Four screw holes, easy positioning.
- Long life and stability, quick response and resume.
MQ135 Module
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 10 - 300 ppm NH3, 10 - 1000 ppm Benzene, 10 - 300 Alcohol
- Sensitivity to Ammonia, Sulphide, and Benzene steam
- With signal output instructions
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Sensitive for benzene, alcohol, smoke
- Fast response and recovery
- Adjustable sensitivity
- Signal output indicator
- Dimension: 32mm x 22m x 27mm
MQ2 Sensor
- Operating Voltage: +5V
- Can be used to Measure or detect LPG, Alcohol, Propane, Hydrogen, CO, and even methane
- Analogue output voltage: 0V to 5V
- Digital Output Voltage: 0V or 5V (TTL Logic)
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- Load resistance: 20 KΩ
- Heater resistance: 33Ω ± 5%
- Heating consumption: <800mw
- Sensing Resistance: 10 KΩ – 60 KΩ
- Detection range: 200 – 10000ppm
- Preheat Time: Over 24 hour
- High sensitivity to LPG, Propane, and Hydrogen
- The Sensitivity of a Digital pin can be varied using the potentiometer
YF G1 Water Flow Sensor
- Working Voltage: DC 4.5V
- Working Voltage: DC 5V~18V
- Flow Rate Range: 2~100L/min
- Water pressure resistance: = >2MPa
- Operating Temperature: = -20~85C
- Insulation resistance: = >100MΩ
- Characteristics of Flow pulse: f=(4.8*Q) Q=L/Min
- Accuracy: ±3%
- Compact, Easy to Install
- High Sealing Performance
- High-Quality Hall Effect Sensor
- RoHS Compliant

Reviews