MQ135 SENSOR
₹230.00 Original price was: ₹230.00.₹180.00Current price is: ₹180.00. inc. GST
- Operating Voltage: 3.3 – 5V.
- Detect/Measure NH3, NOx, alcohol, Benzene, smoke, CO2, etc.
- Analog output voltage: 0V to 5V
- Digital output voltage: 0V or 5V (TTL Logic)
- Detection range:10 ppm-300 ppm NH3, 10 ppm-1000 ppm Benzene, 10 ppm-300 ppm
Alcohol - Heating voltage (high): 5V ± 0.1
- Heating voltage (low): 1.4V ± 0.1
- Load resistance: Adjustable
- Heating resistance: 33Ω ± 5%
- Heating consumption: less than 800mW
- Detection temperature: 20℃±2℃
- Relative humidity: 65%+-5%RH
- Preheat duration 20 seconds
- Can be used as a digital or analogue sensor
- The sensitivity of Digital pin can be varied using the potentiometer
- It has a long life and low cost.
- Possesses high sensitivity to ammonia, benzene, sulfide gases.
- simple drive circuit
A GAS sensor or a GAS Detector is defined as a chemical sensor that detects/measures the concentration of gas in its vicinity. MQ135 sensor is ideal for detection or measuring of NH3, Sulphide, and Benzene steam, smoke and other harmful gases. It offers very good sensitivity and a fast response time makes it ideal such as used in air quality control types of equipment.
The MQ135 sensor operates at a voltage from 2.5V to 5.0V providing a lower conductivity to clean the air as a gas sensing material. But due to the pollution, the conductivity of the gas sensor increases as the concentration of polluting gas increases. It has the potential power to detect different harmful gases. The boost converter of the chip in this air quality sensor is PT1301.
MQ135 sensor is a Tin oxide semiconductor sensor designed explicitly to detect ammonia, nitrogen oxide, smoke, CO2, and other harmful gases. The air quality sensor can detect gas either by digital pin or by analogue pin. The digital low signal light is accessed through the IO ports on the Microcontroller. The analogue output is a concentration, i.e. increasing voltage is directly proportional to increasing concentration. By using the external load resistance the resistance variation is converted into a suitable voltage variation. A small potentiometer in this air quality sensor permits the adjustment of the load resistance of the sensor circuit. This sensor features long life, low cost, and reliable stability make it particularly suitable for Air quality monitoring applications.
Applications:
- Air quality monitor
- Detection of harmful gases
- Domestic air pollution detection
- Industrial pollution detection
- Portable air pollution detection

Related products
Flex Sensor 2.2”
- Flex length: 5.6 cm
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life:1 million
- Flat Resistance: 25K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 45K to 125K Ohms(depending on the bend)
- Total Length: 2.2″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:14.6 x 9.8 x 4.6 cm
- Weight: 30 Grams
Flex Sensor 4.5”
- Operating voltage: 0-5V
- Power rating: 0.5Watt (continuous), 1 Watt (peak)
- Life>1 million
- Flat Resistance: 10K Ω
- Resistance Tolerance: ±30%
- Bend Resistance Range: 60K to 110KOhms(depending on the bend)
- Total Length: 4.5″
- Bends and Flexes physically with the motion device.
- Simple Construction.
- Dimension:11*1*5cm
- Weight: 400gm
LDR SENSOR 20mm
LM35 SENSOR
- Calibrated Directly in Celsius (Centigrade)
- Operates from 4 V to 30 V
- Linear + 10-mV/°C Scale Factor
- ±0.5°C Ensured Accuracy (at 25°C)
- Can measure temperature ranging from -55°C to 150°C
- Less than 60-µA Current Drain
- Low Self-Heating, 0.08°C in Still Air
- Non-Linearity Only ±¼°C Typical
- Low-Impedance Output, 0.1 Ω for 1-mA Load.
- Drain current is less than 60uA
- The output voltage is directly proportional (Linear) to temperature (i.e.) there will be a rise of 10mV (0.01V) for every 1°C rise in temperature
- Suitable for Remote Applications
- Low-cost temperature sensor
- Available in TO-92, TO-220, TO-CAN, and SOIC package
MQ135 Module
- Working voltage: DC 5V
- Working Current: 150mA
- DOUT: TTL output
- AOUT: Analog output
- Preheat time: Over 20s
- Detection Range: 10 - 300 ppm NH3, 10 - 1000 ppm Benzene, 10 - 300 Alcohol
- Sensitivity to Ammonia, Sulphide, and Benzene steam
- With signal output instructions
- The TTL output signal is a low level
- Analog 0 ~ 5 v voltage output, the higher the concentration, the higher the voltage
- Sensitive for benzene, alcohol, smoke
- Fast response and recovery
- Adjustable sensitivity
- Signal output indicator
- Dimension: 32mm x 22m x 27mm
MQ303 Sensor
- Gas: Alcohol ( ethanol )
- Detection range : 20 to 1000ppm
- Characteristics of gas: 125ppm alcohol
- Sensitivity: R in air / Rin typical gas 3
- Sensing Resistance: 4 to 400K in air atmosphere
- Response time : 10s (70% Response)
- Recovery time : 30s (70% Response)
- Heating resistor: 4.5 Ω ± 0.5 Ω
- Heating current: 130mA
- Heating voltage : 0.9V ± 0.10V
- Heating power: 130mW
- Measure the voltage: 24V
- concentration range: 20 to 10,000 ppm
- Working conditions :
- - Ambient temperature : -20 ~ +55
- - Humidity: 95% RH
- - Environmental oxygen content: 21%
- Storage conditions :
- - Temperature : -20 ~ +70
- - Humidity: 70% RH
- High sensitivity
- Fast response and resume
- Long life and low cost
- For ethanol, vapour has high sensitivity and good selectivity
- Simple drive circuit
- Dimensions: 60mm x90mm x9mm
- Weight: 5g
MQ5 SENSOR
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: LPG, natural gas, town gas
- Detection Concentration: 300-10000ppm
- Heating voltage: 5V±0.1
- Load resistance: 20KΩ
- Heater resistance: 31±10%
- Heating consumption: less than 800mw
- Operating temperature:-10 to 50°C
- Related humidity less than 95%Rh
- Sensing Resistance: 10KΩ- 60KΩ (1000ppm CH4)
- Preheat time: Over 24 hour
TCRT5000
- Model TCRT5000
- Colour: Black + blue
- Operating Voltage Range: 3.6~5 VDC
- Package type: leaded
- Typical output current under test: IC = 1 mA
- Emitter wavelength: 950 nm
- Peak operating distance: 2.5 mm
- Detecting range: 0.591″ (15mm)
- Detecting method: Reflective
- Collector-Emitter: Voltage: 70V
- Collector Current: 100mA
- Forward Current: 60mA
- Output type: Phototransistor
- Lead (Pb)-free soldering released
- Daylight blocking filter
- Dimensions: 10.2 x 5.8 x 7mm